Ambient Temperature (°C)
-25...80
Ambient temperature [°C]
-25...80
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20; (scalable 1:5)
Analog Voltage Output (V)
0...10
Analog voltage output [V]
0...10; (scalable 1:5)
Binary Switching Information
2
Characteristics Deviation (% of The Span)
< ± 0, 25 (BFSL) / < ± 0, 5 (LS)
Communication Interface
IO-Link
Conditionally Suitable for
use in gases at pressures > 25 bar only on request
Connector
1 x M12; coding: A; Contacts: gold-plated
Current Consumption (Ma)
< 35
Current consumption [mA]
< 35
Damping for The Analog Output dAA (S)
0...4
Damping for the analog output dAA [s]
0...4
Damping Process Value dAP (S)
0...4
Damping process value dAP [s]
0...4
Delay Time Programmable Ds, Dr (S)
0...50
Delay time programmable dS, dr [s]
0...50
Device Status
4
Dimensions (mm)
Ø 34 / L = 90.7
Dimensions [mm]
Ø 34 / L = 90.7
Display Unit
3 x LED, green (bar, psi, MPa)
Electrical Design
PNP / NPN
File Number UL
E174189
Housing
Tubular
Hysteresis Deviation (% of The Span)
< ± 0, 1
Hysteresis deviation [% of the span]
< ± 0, 1; (Turn down 1:1)
Integrated Watchdog
Yes
IO-Link Functions (Acyclical)
Application Specific Tag
IO-Link Resolution Pressure (Bar)
0.05
IO-Link resolution pressure [bar]
0.05
IO-Link Revision
1.1
Long-term Stability (% of The Span)
< ± 0, 05
Long-term stability [% of the span]
< ± 0, 05; (Turn down 1:1; per 6 months)
Material
stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
Materials (Wetted Parts)
stainless steel (1.4404 / 316L); Al2O3 (ceramics); FKM
Max. load [Ω]
500
Max. response time analog output [ms]
3
Max. voltage drop switching output DC [V]
2
Maximum Load (Ω)
500
Maximum Response Time Analog Output (Ms)
3
Maximum Voltage Drop Switching Output DC (V)
2
Measured Values
alphanumeric display, red / green 4-digit
Measuring Element
Ceramic-capacitive Pressure Measuring Cell
Media
Liquids and Gases
Medium Temperature (°C)
-25...80
Medium temperature [°C]
-25...80
Min. insulation resistance [MΩ]
100; (500 V DC)
Min. load resistance [Ω]
2000
Min. pressure cycles
100 million
Min. process cycle time [ms]
3
Minimum Insulation Resistance (MΩ)
100
Minimum Load Resistance (Ω)
2000
Minimum Pressure Cycles
100 million
Minimum Process Cycle Time (Ms)
3
MTTF (Years)
166
MTTF [years]
166
Notes On The Accuracy / Deviation
switch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1%
Number of Analog Outputs
1
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC; (to SELV/PELV)
Output Function
Normally Open / Closed
Output Signal
switching signal; analog signal; IO-Link
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
250
Permanent current rating of switching output DC [mA]
250
Power-on Delay Time (S)
0.3
Power-on delay time [s]
0.3
Pressure
16
Process Connection
threaded connection G 1 / 4 Internal thread (DIN EN ISO 1179-2)
Protection
IP 65; IP 67
Protection Class
III
Repeatability (% of The Span)
< ± 0, 1
Required master port class
A; (when pin 2 not connected: B)
Response Time (Ms)
< 1.5
Response time [ms]
< 1.5
Restrictor Element Integrated
No (Can Be Retrofitted)
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9
Short-circuit Protection
Yes
SIO mode
Yes
Special feature
Gold-plated contacts
Storage Temperature (°C)
-40...100
Storage temperature [°C]
-40...100
Switch Point Accuracy (% of The Span)
< ± 0, 4
Switch point accuracy [% of the span]
< ± 0, 4; (Turn down 1:1)
Switching Frequency DC (Hz)
< 500
Switching frequency DC [Hz]
< 500
Switching Status
2 x LED, yellow
Temperature Coefficient Span (% of The Span / 10 K)
< ± 0, 2
Temperature coefficient span [% of the span / 10 K]
< ± 0, 2; (-0...80 °C)
Temperature Coefficient Zero Point (% of The Span / 10 K)
< ± 0, 2
Temperature coefficient zero point [% of the span / 10 K]
< ± 0, 2; (-0...80 °C)
Tightening Torque (Nm)
25...35
Total Number of Outputs
2
Transmission type
COM2 (38, 4 kBaud)
Type of Pressure
Relative Pressure
Type of Short-circuit Protection
Yes (Non-latching)
- Two switching outputs, one of them programmable as IO-Link and one as analog output
- Red/green display for clear identification of the acceptable range
- The process connection can be rotated for optimum alignment
- With long-term stability thanks to high overload protection
- Robust design for use in harsh industrial environments
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Dodge
Model
233650
Brand
Drillco
Model
580E023
Brand
Timken
Model
NU217EMA
Brand
U.S.Tsubaki
Model
35B12FH
Brand
Dodge
Model
295980
Brand
Berkeley
Model
B74454
Brand
Walter
Model
4550