We never sell your data to third parties
$484.33 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Ambient Temperature (°C)
-25...80
Ambient temperature [°C]
-25...80
Binary Switching Information
2
Characteristics Deviation (% of The Span)
< ± 0, 25 (BFSL) / < ± 0, 5 (LS)
Communication Interface
IO-Link
Connector
1 x M12; coding: A; Contacts: gold-plated
Current Consumption (Ma)
< 35
Current consumption [mA]
< 35
Delay Time Programmable Ds, Dr (S)
0...50
Delay time programmable dS, dr [s]
0...50
Device Status
4
Dimensions (mm)
Ø 34 / L = 90.7
Dimensions [mm]
Ø 34 / L = 90.7
Display Unit
3 x LED, green (bar, psi, MPa)
Electrical Design
PNP / NPN
Factory Setting / CMPT = 2
453
Housing
Tubular
Hysteresis Deviation (% of The Span)
< ± 0, 25
Hysteresis deviation [% of the span]
< ± 0, 25
Integrated Watchdog
Yes
IO-Link Functions (Acyclical)
Application Specific Tag
IO-Link Revision
1.1
Long-term Stability (% of The Span)
< ± 0, 05
Long-term stability [% of the span]
< ± 0, 05; (per 6 months)
Material
stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
Materials (Wetted Parts)
stainless steel (1.4404 / 316L); ceramics; FKM
Max. voltage drop switching output DC [V]
2.5
Maximum Voltage Drop Switching Output DC (V)
2.5
Measured Values
alphanumeric display, red / green 4-digit
Measuring Element
Ceramic-capacitive Pressure Measuring Cell
Media
Liquids and Gases
Medium Temperature (°C)
-25...80
Medium temperature [°C]
-25...80
Min. insulation resistance [MΩ]
100; (500 V DC)
Min. pressure cycles
100 million
Min. process cycle time [ms]
2.3
Minimum Insulation Resistance (MΩ)
100
Minimum Pressure Cycles
100 million
Minimum Process Cycle Time (Ms)
3
MTTF (Years)
260
MTTF [years]
260
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC; (to SELV/PELV)
Output Function
Normally Open / Closed
Output Signal
switching signal; IO-Link
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
150; (200 (...60 °C) 250 (...40 °C))
Permanent current rating of switching output DC [mA]
150; (200 (...60 °C) 250 (...40 °C))
Power-on Delay Time (S)
< 0.3
Power-on delay time [s]
< 0.3
Pressure
16
Process Connection
threaded connection 1 / 4" NPT Internal thread
Protection
IP 65; IP 67
Protection Class
III
Repeatability (% of The Span)
< ± 0, 1
Repeatability [% of the span]
< ± 0, 1; (with temperature fluctuations < 10 K)
Required master port class
A; (when pin 2 not connected: B)
Response Time (Ms)
< 3
Response time [ms]
< 3
Restrictor Element Integrated
No (Can Be Retrofitted)
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9
Short-circuit Protection
Yes
SIO mode
Yes
Special feature
Gold-plated contacts
Status_B High Resolution / CMPT = 3
631
Storage Temperature (°C)
-40...100
Storage temperature [°C]
-40...100
Switch Point Accuracy (% of The Span)
< ± 0, 5
Switch point accuracy [% of the span]
< ± 0, 5
Switching Frequency DC (Hz)
< 170
Switching frequency DC [Hz]
< 170
Switching Status
2 x LED, yellow
Temperature Coefficient Span (% of The Span / 10 K)
< ± 0, 2
Temperature coefficient span [% of the span / 10 K]
< ± 0, 2; (-0...80 °C)
Temperature Coefficient Zero Point (% of The Span / 10 K)
< ± 0, 2
Temperature coefficient zero point [% of the span / 10 K]
< ± 0, 2; (-0...80 °C)
Total Number of Outputs
2
Transmission type
COM2 (38, 4 kBaud)
Type of Pressure
Relative Pressure
Type of Short-circuit Protection
Yes (Non-latching)
- Two switching outputs, one of them with IO-Link communication interface
- Red/green display for clear identification of the acceptable range
- The process connection can be rotated for optimum alignment
- With long-term stability thanks to high overload protection
- Robust design for use in harsh industrial environments
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
U.S.Tsubaki
Model
50B35F-1H
Brand
IFM
Model
E23006
Brand
Walter
Model
012209
Brand
Thomson Linear
Model
SSEPBOAM25DD
Brand
EXAIR
Model
8042
Brand
Timken
Model
NU3068EMA