Returnable: Yes
Ambient Temperature (°C)
0...60
Ambient temperature [°C]
0...60
Analog Current Output (Ma)
4...20, invertible
Analog current output [mA]
4...20, invertible; (scalable)
Analog Voltage Output (V)
0...10 / 1...5, invertible
Analog voltage output [V]
0...10 / 1...5, invertible; (scalable)
BLOB
Binary Large Object Transfer
Characteristics Deviation (% of The Span)
< ± 0, 5
Communication Interface
IO-Link
Conditionally Suitable for
Other Media On Request
Connector
1 x M8; coding: A; Contacts: 4, gold-plated
Current Consumption (Ma)
< 30
Current consumption [mA]
< 30
Damping for The Analog Output dAA (S)
0...99.99
Damping for the analog output dAA [s]
0...99.99
Damping Process Value dAP (S)
0...4
Damping process value dAP [s]
0...4
Device Status
4
Dimensions (mm)
37.7 x 30 x 38.6
Dimensions [mm]
37.7 x 30 x 38.6
Display 1"
128 x 96 pixels
Display Unit
mbar; kPa; mmHg; kgf / cm²
Electrical Design
PNP / NPN
File Number UL
E174189
Housing
Rectangular
Hysteresis Deviation (% of The Span)
< ± 0, 25
Hysteresis deviation [% of the span]
< ± 0, 25; (Turn down 1:1)
Integrated Watchdog
Yes
IO-Link Resolution Pressure (Bar)
0.0001
IO-Link resolution pressure [bar]
0.0001
IO-Link Revision
1.1.3
Linearity Deviation (% of The Span)
< ± 0.5 % (limit value setting according to DIN EN IEC 62828-1) Turn down 1:1
Long-term Stability (% of The Span)
< ± 0, 1
Long-term stability [% of the span]
< ± 0, 1; (Turn down 1:1; per year)
Material
PBT; PC; TPE; NBR; FKM; brass; silicon (coated)
Materials (Wetted Parts)
PBT; FKM; brass; silicon (coated)
Max. load [Ω]
500
Max. voltage drop switching output DC [V]
2.5
Maximum Load (Ω)
500
Maximum Voltage Drop Switching Output DC (V)
2.5
Media
Compressed Air; Nitrogen (N2)
Medium Temperature (°C)
0...60
Medium temperature [°C]
0...60
Min. insulation resistance [MΩ]
100; (500 V DC)
Min. load resistance [Ω]
2000
Min. pressure cycles
50 million
Min. process cycle time [ms]
0.6
Minimum Insulation Resistance (MΩ)
100
Minimum Load Resistance (Ω)
2000
Minimum Pressure Cycles
50 million
Minimum Process Cycle Time (Ms)
0.6
MTTF (Years)
392
MTTF [years]
392
Number of Analog Outputs
1
Number of Digital Outputs
1
Number of inputs and outputs
Number of digital outputs: 1; Number of analog outputs: 1
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC
Output Function
Normally Open / Closed
Output Signal
switching signal; analog signal; IO-Link
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
100
Permanent current rating of switching output DC [mA]
100
Power-on Delay Time (S)
0.3
Power-on delay time [s]
0.3
Pressure
16
Pressure Equipment Directive
Sound Engineering Practice; Can Be Used for Stable Gases Fluid Group 2
Process Connection
Threaded Connection G 1 / 8 Internal Thread (2X)
Process data analog
1
Process data binary
2
Protection
IP 65
Protection Class
III
Repeatability (% of The Span)
< ± 0, 1
Required master port class
A
Response Time (Ms)
6
Response time [ms]
6
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9: 2019-06
Short-circuit Protection
Yes
SIO mode
Yes
Special feature
Gold-plated contacts
SSC1.1
1
SSC1.2
1
Storage Temperature (°C)
-25...85
Storage temperature [°C]
-25...85
Switch Point Accuracy (% of The Span)
< ± 0, 5
Switch point accuracy [% of the span]
< ± 0, 5; (Turn down 1:1)
Switching Frequency DC (Hz)
< 170
Switching frequency DC [Hz]
< 170
Switching Status
1 x LED, yellow
Temperature Coefficient Span (% of The Span / 10 K)
0, 2
Temperature coefficient span [% of the span / 10 K]
0, 2; (Turn down 1:1)
Temperature Coefficient Zero Point (% of The Span / 10 K)
0, 2
Temperature coefficient zero point [% of the span / 10 K]
0, 2; (Turn down 1:1)
Total Number of Outputs
2
Transmission type
COM3 (230, 4 kBaud)
Type of Pressure
Relative Pressure; Vacuum
Type of Short-circuit Protection
Yes (Non-latching)
- Reliable monitoring of the system pressure in pneumatics and in compressed air systems
- Very high overpressure and vacuum resistance
- Clearly visible TFT display
- Red/green display for clear identification of the acceptable range
- With programmable switching output and analog output
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Walter
Model
9515
Brand
Berkeley
Model
B74777
Brand
Wiegmann
Model
N412423610C
Brand
Drillco
Model
20C232FP
Brand
Whitney Tool
Model
01002
Brand
Thomson Linear
Model
511H25C1C
Brand
Flexco
Model
02866
Brand
Timken
Model
6305