We never sell your data to third parties
$193.71 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Ambient Temperature (°C)
-40...90
Ambient temperature [°C]
-40...90
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20
Characteristics Deviation (% of The Span)
< ± 0, 5
Connector
1 x M12; coding: A
Dimensions (mm)
Ø 18.9 / L = 66.9
Dimensions [mm]
Ø 18.9 / L = 66.9
Housing
Tubular
Hysteresis Deviation (% of The Span)
< ± 0, 2
Hysteresis deviation [% of the span]
< ± 0, 2
Linearity Deviation (% of The Span)
< ± 0, 1 (BFSL) / < ± 0, 2 (LS)
Linearity deviation [% of the span]
< ± 0, 1 (BFSL) / < ± 0, 2 (LS)
Long-term Stability (% of The Span)
< ± 0, 1
Long-term stability [% of the span]
< ± 0, 1; (per 6 months)
Material
stainless steel (630 / 1.4542 / 17-4 PH); stainless steel (1.4404 / 316L); PEI
Materials (Wetted Parts)
stainless steel (630 / 1.4542 / 17-4 PH)
MAWP (for Applications According To CRN) (Psi)
940
MAWP (for applications according to CRN) [psi]
940
Max. load [Ω]
720; (Ub = 24 V; (Ub - 8, 5 V) / 21, 5 mA)
Maximum Load (Ω)
720; (Ub = 24 V; (Ub - 8, 5 V) / 21, 5 mA)
Media
Liquids and Gases
Medium Temperature (°C)
-40...90
Medium temperature [°C]
-40...90
Min. insulation resistance [MΩ]
100; (500 V DC)
Min. pressure cycles
60 million; (at 1.2 times nominal pressure)
Minimum Insulation Resistance (MΩ)
100
Minimum Pressure Cycles
60 million
MTTF (Years)
789
MTTF [years]
789
Number of Analog Outputs
1
Number of inputs and outputs
Number of analog outputs: 1
Operating Voltage (V)
8.5...36 DC
Operating voltage [V]
8.5...36 DC
Output Signal
Analog Signal
Overload Protection
Yes
Pack quantity
1 pcs.
Process Connection
threaded connection 1 / 4" NPT external thread
Protection
IP 67; IP 69K
Protection Class
III
Repeatability (% of The Span)
< ± 0, 05
Repeatability [% of the span]
< ± 0, 05; (with temperature fluctuations < 10 K)
Restrictor Element Integrated
Yes
Reverse Polarity Protection
Yes
Short-circuit Proof
Yes
Step Response Time Analog Output (Ms)
2
Step response time analog output [ms]
2
Storage Temperature (°C)
-40...100
Storage temperature [°C]
-40...100
Temperature Coefficient Zero Point and Span (% of The Span / 10 K)
< 0, 1 (-25...90 °C) / < 0, 2 (-40...-25 °C)
Temperature coefficient zero point and span [% of the span / 10 K]
< 0, 1 (-25...90 °C) / < 0, 2 (-40...-25 °C)
Tightening Torque (Nm)
< 50
Total Number of Outputs
1
Type of Pressure
Relative Pressure
- Reliable detection of system pressure in industrial applications
- High shock and vibration resistance
- Excellent repeatability and low linearity error
- Lifespan of more than 60 million pressure cycles
- Compact and robust stainless steel housing for use where space is restricted
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Martin Sprocket
Model
E7-20TSA-36-04
Brand
AMI Bearings
Model
UCWTPL208CB
Brand
Walter
Model
9800-77
Brand
Timken
Model
240462
Brand
IFM
Model
E10023
Brand
Dormer Pramet
Model
5983776
Brand
Meltric
Model
6118073
Brand
Dormer Pramet
Model
A14711.2