Returnable: Yes

Ambient Temperature (°C)

-40...100

Ambient temperature [°C]

-40...100

Analog Current Output (Ma)

4...20

Analog current output [mA]

4...20

Characteristics Deviation (% of The Span)

< ± 0, 8

Connector

1 x M12; coding: A; Maximum cable length: 30 m

Dimensions (mm)

Ø 19 / L = 66

Dimensions [mm]

Ø 19 / L = 66

Housing

Tubular

Hysteresis Deviation (% of The Span)

< ± 0, 2

Hysteresis deviation [% of the span]

< ± 0, 2

ISO 11452-2

100 V / m

Linearity Deviation (% of The Span)

< ± 0, 25 (BFSL) / < ± 0, 5 (LS)

Linearity deviation [% of the span]

< ± 0, 25 (BFSL) / < ± 0, 5 (LS)

Long-term Stability (% of The Span)

< ± 0, 1

Long-term stability [% of the span]

< ± 0, 1; (per 6 months)

Material

stainless steel (630 / 1.4542 / 17-4 PH); stainless steel (1.4404 / 316L); PEI

Materials (Wetted Parts)

stainless steel (630 / 1.4542 / 17-4 PH)

Maximum Load (Ω)

(Ub - 8 V) / 21, 5 mA; @8V = 0 Ω; @12V max. 200 Ω; @24V max. 750 Ω

Media

Liquids and Gases

Medium Temperature (°C)

-40...125

Medium temperature [°C]

-40...125

Min. insulation resistance [MΩ]

100; (500 V DC)

Min. pressure cycles

60 million; (at 1.2 times nominal pressure)

Minimum Insulation Resistance (MΩ)

100

Minimum Pressure Cycles

60 million

MTTF (Years)

711

MTTF [years]

711

Number of Analog Outputs

1

Number of inputs and outputs

Number of analog outputs: 1

Operating Voltage (V)

8...32 DC

Operating voltage [V]

8...32 DC

Output Signal

Analog Signal

Overload Protection

Yes

Pack quantity

1 pcs.

Power-on Delay Time (S)

< 0.1

Power-on delay time [s]

< 0.1

Process Connection

threaded connection G 1 / 4 external thread (DIN EN ISO 1179-2)

Process Connection Sealing

HNBR (DIN EN ISO 1179-2)

Protection

IP 67; IP 69K

Protection Class

III

Repeatability (% of The Span)

< ± 0, 05

Repeatability [% of the span]

< ± 0, 05; (with temperature fluctuations < 10 K)

Restrictor Element Integrated

Yes

Reverse Polarity Protection

Yes

Short-circuit Proof

Yes

Step Response Time Analog Output (Ms)

2

Step response time analog output [ms]

2

Storage Temperature (°C)

-40...100

Storage temperature [°C]

-40...100

Temperature Coefficient Span (% of The Span / 10 K)

< ± 0, 1 (0...80 °C); < ± 0, 2 (-40...0 °C / 80...125 °C)

Temperature coefficient span [% of the span / 10 K]

< ± 0, 1 (0...80 °C); < ± 0, 2 (-40...0 °C / 80...125 °C)

Temperature Coefficient Zero Point (% of The Span / 10 K)

< ± 0, 1 (0...80 °C); < ± 0, 2 (-40...0 °C / 80...125 °C)

Temperature coefficient zero point [% of the span / 10 K]

< ± 0, 1 (0...80 °C); < ± 0, 2 (-40...0 °C / 80...125 °C)

Tightening Torque (Nm)

25...35

Total Number of Outputs

1

Type of Pressure

Relative Pressure

  • For the reliable detection of the system pressure in mobile machines
  • Robust stainless steel housing with high shock and vibration resistance
  • Compact housing for use where space is restricted
  • Lifespan of more than 60 million pressure cycles
  • With long-term stability thanks to high repeatability and low linearity error

Aug. 15, 2019

PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.

Read More

 
Aug. 14, 2019

When selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.

Read More

 
Recently Viewed
E12B-4O/L

#2794745

Brand

PTI

Model

E12B-4O/L

$22.76 Each
Free Shipping orders over $100
ALEDL2TSFN/WS2

#6510553

Brand

RAB Lighting

Model

ALEDL2TSFN/WS2

$1,627.00 Each Add to cart for a lower price
Free shipping
32360

#2927436

Brand

Timken Drives

Model

32360

$43.83 Per Foot
Free Shipping orders over $100
RAIL175N

#6513839

Brand

RAB Lighting

Model

RAIL175N

$539.00 Each Add to cart for a lower price
Free shipping
94208

#5676191

Brand

Airmaster

Model

94208

Call for pricing
94226

#5676209

Brand

Airmaster

Model

94226

Call for pricing
SPLN030FSS

#96703861

Brand

Thomson Linear

Model

SPLN030FSS

$303.03 Each
Free shipping
064615

#688567

Brand

Dodge

Model

064615

$560.32 Each Add to cart for a lower price
Free shipping