Image for Illustration purposes only. Actual product may vary

View in markdown

IFM PU5703 PU-025-SEG14-B-DVG/DE Pressure transmitter

MODEL PU5703

BRAND

IFM

SKU

96946033

UOM

each

$181.94 Each

Prices are subject to change

FREE SHIPPING ON ORDERS OVER $100

Select Quantity

GET A QUOTE

Returnable: Yes

Ambient Temperature (°C)

-40...100

Ambient temperature [°C]

-40...100

Analog Voltage Output (V)

0...10

Analog voltage output [V]

0...10

Characteristics Deviation (% of The Span)

< ± 0, 8

Compliant with UN ECE R10, Rev. 5

(E1 compliant)

Connector

1 x DEUTSCH connector (DT04-3P); Maximum cable length: 30 m

Current Consumption (Ma)

< 12

Current consumption [mA]

< 12

Dimensions (mm)

Ø 19 / L = 71.5

Dimensions [mm]

Ø 19 / L = 71.5

Housing

Tubular

Hysteresis Deviation (% of The Span)

< ± 0, 2

Hysteresis deviation [% of the span]

< ± 0, 2

ISO 11452-2

100 V / m

Linearity Deviation (% of The Span)

< ± 0, 25 (BFSL) / < ± 0, 5 (LS)

Linearity deviation [% of the span]

< ± 0, 25 (BFSL) / < ± 0, 5 (LS)

Long-term Stability (% of The Span)

< ± 0, 1

Long-term stability [% of the span]

< ± 0, 1; (per 6 months)

Material

stainless steel (630 / 1.4542 / 17-4 PH); stainless steel (1.4404 / 316L); PPS

Materials (Wetted Parts)

stainless steel (630 / 1.4542 / 17-4 PH)

Media

Liquids and Gases

Medium Temperature (°C)

-40...125

Medium temperature [°C]

-40...125

Min. insulation resistance [MΩ]

100; (500 V DC)

Min. load resistance [Ω]

2000

Min. pressure cycles

60 million; (at 1.2 times nominal pressure)

Minimum Insulation Resistance (MΩ)

100

Minimum Load Resistance (Ω)

2000

Minimum Pressure Cycles

60 million

MTTF (Years)

640

MTTF [years]

640

Number of Analog Outputs

1

Number of inputs and outputs

Number of analog outputs: 1

Operating Voltage (V)

16...32 DC

Operating voltage [V]

16...32 DC

Output Signal

Analog Signal

Overload Protection

Yes

Pack quantity

1 pcs.

Power-on Delay Time (S)

< 0.1

Power-on delay time [s]

< 0.1

Process Connection

threaded connection G 1 / 4 external thread (DIN EN ISO 1179-2)

Process Connection Sealing

HNBR (DIN EN ISO 1179-2)

Protection

IP 67; IP 69K

Protection Class

III

Repeatability (% of The Span)

< ± 0, 05

Repeatability [% of the span]

< ± 0, 05; (with temperature fluctuations < 10 K)

Restrictor Element Integrated

Yes

Reverse Polarity Protection

Yes

Short-circuit Proof

Yes

Step Response Time Analog Output (Ms)

2

Step response time analog output [ms]

2

Storage Temperature (°C)

-40...100

Storage temperature [°C]

-40...100

Temperature Coefficient Span (% of The Span / 10 K)

< ± 0, 1 (0...80 °C); < ± 0, 3 (-40...0 °C); < ± 0, 2 (80...125 °C)

Temperature Coefficient Zero Point (% of The Span / 10 K)

< ± 0, 1 (0...80 °C); < ± 0, 2 (-40...0 °C / 80...125 °C)

Temperature coefficient zero point [% of the span / 10 K]

< ± 0, 1 (0...80 °C); < ± 0, 2 (-40...0 °C / 80...125 °C)

Tightening Torque (Nm)

25...35

Total Number of Outputs

1

Type of Pressure

Relative Pressure

  • For the reliable detection of the system pressure in mobile machines
  • Robust stainless steel housing with high shock and vibration resistance
  • Compact housing for use where space is restricted
  • DEUTSCH connector for the fast and easy connection to the on-board system
  • With long-term stability thanks to high repeatability and low linearity error

Aug. 15, 2019

PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.

Read More

 
Aug. 14, 2019

When selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.

Read More

 
Recently Viewed
043261

#96656245

Brand

Dodge

Model

043261

$85.50 Each
Free Shipping orders over $100
K11BAD596

#97178061

Brand

Senco

Model

K11BAD596

$62.33 Each
Free Shipping orders over $100
400AX104

#97172043

Brand

Drillco

Model

400AX104

$3.73 Each
Free Shipping orders over $100
69908120169

#97187486

Brand

FEIN

Model

69908120169

$29.21 Each
Free Shipping orders over $100
410N123

#97172071

Brand

Drillco

Model

410N123

$6.29 Each
Free Shipping orders over $100
IB5096

#96944520

Brand

IFM

Model

IB5096

$159.94 Each
Free shipping
F4B-SCED-215

#791551

Brand

Dodge

Model

F4B-SCED-215

$426.39 Each Add to cart for a lower price
Free shipping