PY9070

Image for Illustration purposes only. Actual product may vary

View in markdown

IFM PY9070 PN-400-SE MFRKG/US/ / Pressure sensor with display

MODEL PY9070

BRAND

IFM

SKU

96946037

UOM

each

$1,870.44 Each

Prices are subject to change

FREE SHIPPING ON ORDERS OVER $100

Select Quantity

GET A QUOTE

Returnable: Yes

Ambient Temperature (°C)

5...80

Ambient temperature [°C]

5...80

Analog Current Output (Ma)

4...20

Analog current output [mA]

4...20; (scalable 1:5)

Analog Voltage Output (V)

0...10

Analog voltage output [V]

0...10; (scalable 1:5)

Characteristics Deviation (% of The Span)

< ± 1

Communication Interface

IO-Link

Connector

1 x M12; coding: A; Contacts: gold-plated

Current Consumption (Ma)

< 35

Current consumption [mA]

< 35

Damping for The Analog Output dAA (S)

0...4

Damping for the analog output dAA [s]

0...4

Damping Process Value dAP (S)

0...4

Damping process value dAP [s]

0...4

Delay Time Programmable Ds, Dr (S)

0...50

Delay time programmable dS, dr [s]

0...50

Dimensions (mm)

Ø 34 / L = 197

Dimensions [mm]

Ø 34 / L = 197

Display Unit

3 x LED, green (bar, psi, MPa)

Electrical Design

PNP / NPN

Housing

Tubular

Hysteresis Deviation (% of The Span)

< ± 0, 1

Hysteresis deviation [% of the span]

< ± 0, 1; (Turn down 1:1)

Integrated Watchdog

Yes

IO-Link Revision

1.1

Long-term Stability (% of The Span)

< ± 0, 05

Long-term stability [% of the span]

< ± 0, 05; (Turn down 1:1; per 6 months)

Materials (Wetted Parts)

Stainless Steel (1.4435 / 316L)

Max. load [Ω]

500

Max. response time analog output [ms]

3

Max. voltage drop switching output DC [V]

2

Maximum Load (Ω)

500

Maximum Response Time Analog Output (Ms)

3

Maximum Voltage Drop Switching Output DC (V)

2

Measured Values

alphanumeric display, red / green 4-digit

Measuring Element

Diaphragm Seal

Media

Liquids and Gases

Medium Temperature (°C)

5...125

Medium temperature [°C]

5...125; (150 maximum 1h)

Min. insulation resistance [MΩ]

100; (500 V DC)

Min. load resistance [Ω]

2000

Min. pressure cycles

60 million; (at 1.2 times nominal pressure)

Min. process cycle time [ms]

2.3

Minimum Insulation Resistance (MΩ)

100

Minimum Load Resistance (Ω)

2000

Minimum Pressure Cycles

60 million

Minimum Process Cycle Time (Ms)

2.3

Number of Analog Outputs

1

Number of Digital Outputs

2

Number of inputs and outputs

Number of digital outputs: 2; Number of analog outputs: 1

Operating Voltage (V)

18...30 DC

Operating voltage [V]

18...30 DC; (to SELV/PELV)

Output Function

Normally Open / Closed

Output Signal

switching signal; analog signal; IO-Link

Overload Protection

Yes

Pack quantity

1 pcs.

Permanent Current Rating of Switching Output DC (Ma)

250

Permanent current rating of switching output DC [mA]

250

Power-on Delay Time (S)

0.3

Power-on delay time [s]

0.3

Process Connection

Homogenizer Connection

Process data analog

1

Process data binary

2

Protection

IP 67

Protection Class

III

Repeatability (% of The Span)

< ± 0, 1

Required master port class

A

Response Time (Ms)

< 1.5

Response time [ms]

< 1.5

Reverse Polarity Protection

Yes

SDCI Standard

IEC 61131-9

Short-circuit Protection

Yes

SIO mode

Yes

Special feature

Gold-plated contacts

Storage Temperature (°C)

-40...100

Storage temperature [°C]

-40...100

Switch Point Accuracy (% of The Span)

< ± 0, 4

Switch point accuracy [% of the span]

< ± 0, 4; (Turn down 1:1)

Switching Frequency DC (Hz)

< 500

Switching frequency DC [Hz]

< 500

Switching Status

2 x LED, yellow

Temperature Coefficient Span (% of The Span / 10 K)

0, 2

Temperature coefficient span [% of the span / 10 K]

0, 2; (5...80 °C)

Temperature Coefficient Zero Point (% of The Span / 10 K)

0, 2

Temperature coefficient zero point [% of the span / 10 K]

0, 2; (5...80 °C)

Total Number of Outputs

2

Transmission type

COM2 (38, 4 kBaud)

Type of Pressure

Relative Pressure

Type of Short-circuit Protection

Yes (Non-latching)

  • Suited for use in homogenizer processes
  • Programmable switching output with IO-Link and scalable analog output
  • Red/green display for clear identification of the acceptable range
  • The process connection can be rotated for optimum alignment

Aug. 15, 2019

PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.

Read More

 
Aug. 14, 2019

When selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.

Read More

 
Recently Viewed
1 L SS CTL

#1814487

Brand

Thomson Linear

Model

1 L SS CTL

$6.86 Per Inch
Free Shipping orders over $100
63134429002

#97185752

Brand

FEIN

Model

63134429002

$158.00 Each
Free shipping
200061

#96662809

Brand

Dodge

Model

200061

Call for pricing
229428

#5005992

Brand

Dodge

Model

229428

$1,250.00 Each
Free shipping
234150

#5008676

Brand

Dodge

Model

234150

$935.46 Each
Free shipping
24801-4947

#5091153

Brand

Timken

Model

24801-4947

$660.29 Each
Free shipping