We never sell your data to third parties
IFM PI1602 PI-100-REA01-MFRKG/US/ /P Flush pressure sensor with display
MODEL PI1602
$796.62 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Typically Ships in: 1 day
Returnable:No
Accuracy (K)
± 2, 5+ (0, 08 x ( Umgebungstemperatur - Mediumtemperatur ))
Accuracy [K]
± 2, 5+ (0, 08 x ( Umgebungstemperatur - Mediumtemperatur ))
Ambient Temperature (°C)
-25...80
Ambient temperature [°C]
-25...80
Analog Current Output (Ma)
4...20, invertible
Analog current output [mA]
4...20, invertible; (scalable)
Binary Switching Information
2
Characteristics Deviation (% of The Span)
< ± 0, 5
Communication Interface
IO-Link
Connector
1 x M12; coding: A; Contacts: 4, gold-plated
Current Consumption (Ma)
5...45
Current consumption [mA]
3.5...21.5
Damping for The Analog Output dAA (S)
0...99.99
Damping for the analog output dAA [s]
0...99.99
Damping Process Value dAP (S)
0...99.99
Damping process value dAP [s]
0...99.99
Device Status
4
Dimensions (mm)
Ø 50 / L = 116
Display Unit
bar; psi; MPa
Display, Switching Output
0, 2
Dynamic Response T05 / T09 (S)
< 45 / < 200
Dynamic response T05 / T09 [s]
< 45 / < 200; (DIN EN 60751 water ; > 0, 9 m/s)
Electrical Design
PNP / NPN
File Number UL
E174189
Function Display
alphanumeric display, 4-digit
Housing
Tubular
Hysteresis Deviation (% of The Span)
< ± 0, 15
Hysteresis deviation [% of the span]
< ± 0, 15; (Turn down 1:1)
Integrated Watchdog
Yes
IO-Link Resolution Pressure (Bar)
0.005
IO-Link resolution pressure [bar]
0.005
IO-Link Resolution Temperature (K)
0.2
IO-Link resolution temperature [K]
0.2
IO-Link Revision
1.1
IO-Link, Analog Output
0, 15
Linearity Deviation (% of The Span)
< ± 0, 15
Linearity deviation [% of the span]
< ± 0, 15; (Turn down 1:1)
Long-term Stability (% of The Span)
< ± 0, 1
Long-term stability [% of the span]
< ± 0, 1; (Turn down 1:1; per year)
Max. load [Ω]
300
Max. voltage drop switching output DC [V]
2
Maximum Load (Ω)
(Ub - 10 V) / 21, 5 mA; 650 Ω (Ub = 24 V)
Maximum Voltage Drop Switching Output DC (V)
2
Measured Values
alphanumeric display, 4-digit
Media
Use in gases at pressures > 25 bar only on request
Medium Temperature (°C)
-25...150
Medium temperature [°C]
-25...150
Min. insulation resistance [MΩ]
100; (500 V DC)
Min. process cycle time [ms]
5.6
Min. response time of switching output (dAP) [ms]
3
Minimum Insulation Resistance (MΩ)
100
Minimum Pressure Cycles
100 million
Minimum Process Cycle Time (Ms)
5.6
Minimum Response Time of Switching Output (dAP) (Ms)
3
MTTF (Years)
214
MTTF [years]
214
NO Dead Space
Yes
Notes on the accuracy / deviation
For further details see section Diagrams and graphs
Number of Analog Outputs
1
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Operating Voltage (V)
18...30 DC
Operating voltage [V]
20...30 DC
Output Function
Normally Open / Closed
Output Signal
switching signal; analog signal; IO-Link
Overload Protection
Yes
Permanent Current Rating of Switching Output DC (Ma)
100
Permanent current rating of switching output DC [mA]
100
Power-on Delay Time (S)
< 0.5
Power-on delay time [s]
< 1
Pressure
32
Process Connection
Threaded Connection G 1 External Thread Sealing Cone
Protection
IP 67; IP 68; IP 69K
Protection Class
III
Repeatability (% of The Span)
< ± 0, 1
Repeatability [K]
± 0, 2
Required master port class
A
Resolution (K)
0.2
Resolution [K]
0.2
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9
Short-circuit Protection
Yes
SIO mode
Yes
Special feature
Gold-plated contacts
Step Response Time Analog Output (Ms)
7
Step response time analog output [ms]
30
Storage Temperature (°C)
-40...100
Storage temperature [°C]
-40...100
Switch Point Accuracy (% of The Span)
< ± 0, 5
Switch point accuracy [% of the span]
< ± 0, 5; (DIN EN IEC 62828-1; Turn down 1:1)
Switching Frequency DC (Hz)
125
Switching frequency DC [Hz]
125
Switching Status
LED, yellow
Temperature
32
Temperature Range
Total Deviation
Tightening Torque (Nm)
20
Total Number of Outputs
2
Transmission type
COM2 (38, 4 kBaud)
Type of Pressure
Relative Pressure; Vacuum
Type of Short-circuit Protection
Yes (Non-latching)
X
Temperature
Y
Total Deviation
- Robust stainless steel design for the requirements of the food and beverage industry
- Hygienic, flush design
- Resistant to high-pressure cleaning with aggressive cleaning agents
- High temperature resistance and high protection rating
- Programmable analog and switching output
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
SealMaster
Model
MFC-64
Brand
Pfannenberg
Model
23350150056
Brand
Timken Drives
Model
57480
Brand
HKK Chain
Model
A2040RL
Brand
U.S.Tsubaki
Model
H40B15
Brand
LubeSite
Model
202-8