We never sell your data to third parties
IFM PP7550 PP-400-SBG14-QFPKG/US/ /V Pressure switch with ceramic measuring cell
MODEL PP7550
$332.86 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Absorber Chamber Test To ISO 11452-2:
80 V / m
Ambient Temperature (°C)
-25...85
Ambient temperature [°C]
-25...85
Characteristics Deviation (% of The Span)
< ± 0, 25 (BFSL) / < ± 0, 5 (LS)
Communication Interface
IO-Link
Conditionally Suitable for
use in gases at pressures > 25 bar only on request
Connector
1 x M12; coding: A; Contacts: 4
Current Consumption (Ma)
< 45
Current consumption [mA]
< 45
Damping Process Value dAP In Steps (S)
0, 003 - 0, 006 - 0, 010 - 0, 017 - 0, 060 - 0, 125 - 0, 250 - 0, 500
Dimensions (mm)
Ø 30 / L = 79.5
Dimensions [mm]
Ø 30 / L = 79.5
DIN IEC 60068-2-27 / DIN IEC 60068-2-29
1000 g
DIN IEC 68-2-6
20 g (10...2000 Hz)
Electrical Design
PNP
Housing
Tubular
Hysteresis Deviation (% of The Span)
< ± 0, 1
Hysteresis deviation [% of the span]
< ± 0, 1
IO-Link
1, 0
IO-Link Revision
1
Long-term Stability (% of The Span)
< ± 0, 1
Long-term stability [% of the span]
< ± 0, 1; (per year)
Material
stainless steel (1.4301 / 304); FKM; EPDM / X; PA
Materials (Wetted Parts)
stainless steel (1.4305 / 303); ceramics; FKM
Max. voltage drop switching output DC [V]
2
Maximum Voltage Drop Switching Output DC (V)
2
Media
Liquids and Gases
Medium Temperature (°C)
-25...90
Medium temperature [°C]
-25...90
Min. insulation resistance [MΩ]
100; (500 V DC)
Min. pressure cycles
100 million
Min. process cycle time [ms]
2.3
Minimum Insulation Resistance (MΩ)
100
Minimum Pressure Cycles
100 million
Minimum Process Cycle Time (Ms)
2.3
MTTF (Years)
310
MTTF [years]
310
Noise Immunity
according to the automotive directive 1995 / 54 / EC / 04 / 104EG / 05 / 83 / EG
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2
Operating Voltage (V)
9.6...36 DC
Operating voltage [V]
9.6...36 DC; (communication mode: 18...32)
Output Function
Normally Open / Closed
Output Signal
switching signal; IO-Link
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
250
Permanent current rating of switching output DC [mA]
250
Power
2 x LED, green
Power-on Delay Time (S)
0.3
Power-on delay time [s]
0.3
Process Connection
threaded connection G 1 / 4 external thread Internal thread:M5
Process data analog
1
Process data binary
2
Protection
IP 68
Protection Class
III
Repeatability (% of The Span)
< ± 0, 1
Repeatability [% of the span]
< ± 0, 1; (with temperature fluctuations < 10 K)
Required master port class
A
Response Time (Ms)
< 3
Response time [ms]
< 3
Restrictor Element Integrated
Yes
Reverse Polarity Protection
Yes
Short-circuit Protection
Yes
SIO mode
Yes
Storage Temperature (°C)
-40...100
Storage temperature [°C]
-40...100
Switch Point Accuracy (% of The Span)
< ± 0, 5
Switch point accuracy [% of the span]
< ± 0, 5
Switching Frequency DC (Hz)
170
Switching frequency DC [Hz]
170
Switching Output, Display
1, 0
Switching Status
2 x LED, yellow
Teach Function
Yes
Temperature Coefficient Span (% of The Span / 10 K)
< ± 0, 2
Temperature coefficient span [% of the span / 10 K]
< ± 0, 2; (0...80 °C)
Temperature Coefficient Zero Point (% of The Span / 10 K)
< ± 0, 2
Temperature coefficient zero point [% of the span / 10 K]
< ± 0, 2; (0...80 °C)
Total Number of Outputs
2
Transmission type
COM2 (38, 4 kBaud)
Type of Pressure
Relative Pressure
Type of Short-circuit Protection
Yes (Non-latching)
- DC PNP
- Adjustment of the switch point by teach function
- Connector
- 2 outputs
- OUT1 = switching output
- OUT2 = switching output or diagnostic output
The industrial sensor is an industrial device category used to serve its stated function within industrial automation equipment. It is incorporated into equipment arrangements where that general function is needed. The configuration details in the list identify this cataloged item and should be considered with the product technical documentation and applicable machine requirements. Catalog number PP7550 distinguishes this item in the equipment record. This paragraph provides general device context only; product-specific technical details are limited to the listed source information.
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Te-Co
Model
57083
Brand
Thomson Linear
Model
511P20D3ES7
Brand
IFM
Model
E70440
Brand
IFM
Model
EVC944
Brand
Dodge
Model
232303
Brand
WEG
Model
CSW-BGA2
Brand
Boston Gear
Model
PL5050-007-0203-09.5
Brand
Flowtrend
Model
60094R1