We never sell your data to third parties
IFM TP2003 TP-FDC-AFZVG/US/ Temperature plug for hygienic applications
MODEL TP2003
$164.45 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Ambient Temperature (°C)
-25...80
Ambient temperature [°C]
-25...80
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20
BLOB
Binary Large Object Transfer
Communication Interface
IO-Link
Degree of Soiling
3
Dimensions (mm)
Ø 27.4 / L = 65
Dimensions [mm]
Ø 27.4 / L = 65
Electrical Design
PNP / NPN
Factory setting
0...300 °F
Housing
Tubular
Integrated Watchdog
Yes
IO-Link Resolution Temperature (K)
0.02
IO-Link resolution temperature [K]
0.02
IO-Link Revision
1.1.3
Material
LED: PA; housing: stainless steel (1.4404 / 316L)
Max. height above sea level [m]
2000
Max. load [Ω]
(Ub-13, 5)/0, 0215
Max. measuring/display cycle [ms]
350
Max. relative air humidity [%]
90; (non condensing)
Max. voltage drop switching output DC [V]
2
Maximum Height Above Sea Level (M)
2000
Maximum Load (Ω)
(Ub-13, 5) / 0, 0215
Maximum Measuring/Display Cycle (Ms)
350
Maximum Relative Air Humidity (%)
90
Maximum Voltage Drop Switching Output DC (V)
2
Measuring Range (°F)
-148...572
Measuring range [°F]
-148...572
Min. process cycle time [ms]
3.2
Minimum Process Cycle Time (Ms)
3.2
MTTF (Years)
462
MTTF [years]
462
Number of Analog Outputs
1
Number of Digital Outputs
1
Number of inputs and outputs
Number of digital outputs: 1; Number of analog outputs: 1
Operating Voltage (V)
18...32 DC
Operating voltage [V]
18...32 DC
Output Function
Normally Open / Closed
Output Signal
analog signal; IO-Link; switching signal
Overload Protection
Yes
Overvoltage Category
II
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
100
Permanent current rating of switching output DC [mA]
100
Pollution degree
3
Power-on Delay Time (S)
2
Power-on delay time [s]
2
Precision Analog Output (K)
± 0, 18; (MS: 0...300 °F); or ± (0, 067 % MS)
Precision analog output [K]
± 0, 18; (MS: 0...300 °F) ; or ± (0, 067 % MS)
Precision IO-Link (K)
± 0, 09
Precision IO-Link [K]
± 0, 09
Protection
IP 68; IP 69K
Protection Class
III
Resolution of Analog Output (K)
0.032
Resolution of analog output [K]
0.032; (MS: 0...300 °F)
Reverse Polarity Protection
Yes
Sealing Material
FKM
Short-circuit Protection
Yes
Special feature
Gold-plated contacts
Status
1 x LED, green
Storage Temperature (°C)
-40...85
Storage temperature [°C]
-40...85
Switching Status
1 x LED, orange
Temperature Coefficient Analog Output (% of The Span / 10 K)
< 0, 1
Temperature coefficient analog output [% of the span / 10 K]
< 0, 1
Temperature Coefficient IO-Link (% of The Span / 10 K)
< 0, 06
Temperature coefficient IO-Link [% of the span / 10 K]
< 0, 06
Total Number of Outputs
2
Transmission type
COM2 (38, 4 kBaud)
Type of Short-circuit Protection
Not Locked In Place
- For the signal evaluation of temperature sensors and resistance thermometers
- Ideal for demanding control tasks thanks to high resolution
- Hygienic stainless steel housing with status LED
- Large temperature measurement range
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Dodge
Model
100569
Brand
Extech
Model
RHT10
Brand
Thomson Linear
Model
413H35A0
Brand
Flowtrend
Model
C216MD-14T-5.25
Brand
Thomson Linear
Model
511U15C3V
Brand
Thomson Linear
Model
MAM30ADJW
Brand
Flowtrend
Model
22340625