Ambient Temperature (°C)
-25...70
Ambient temperature [°C]
-25...70
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20
BLOB
Binary Large Object Transfer
Calibration Check Limit (K)
0.5...3
Calibration check limit [K]
0.5...3
Communication Interface
IO-Link
Connector
1 x M12; coding: A; Contacts: gold-plated
Current Consumption (Ma)
10
Current consumption [mA]
10; (24 V)
Diagnostic Output
Calibration Check Status and Error Diagnostics
Dimensions (mm)
Ø 50 / L = 144
Dimensions [mm]
Ø 50 / L = 144
Dynamic Response T05 / T09 (S)
1, 5 / 4
Dynamic response T05 / T09 [s]
1, 5 / 4
Electrical Design
PNP / NPN
Factory setting
14...302 °F
File Number UL
E217884
Housing
Tubular
In Steps of (K)
0.05
In steps of [K]
0.05
Installation Length EL (mm)
50
Installation length EL [mm]
50
Integrated Watchdog
Yes
IO-Link Resolution Temperature (K)
0.01
IO-Link resolution temperature [K]
0.01
IO-Link Revision
1.1
Material
stainless steel (1.4404 / 316L); PEI; FKM; PFA
Materials (Wetted Parts)
stainless steel (1.4404 / 316L); PEEK
Max. load [Ω]
(Ub - 15 V) x 50
Max. voltage drop switching output DC [V]
2
Maximum Load (Ω)
(Ub - 15 V) x 50
Maximum Voltage Drop Switching Output DC (V)
2
Measuring Element
1 x Pt 1000
Media
Liquids and Gases
Min. process cycle time [ms]
4.4
Minimum Installation Depth (mm)
15
Minimum installation depth [mm]
15
Minimum Process Cycle Time (Ms)
4.4
MTTF (Years)
329
MTTF [years]
329
Number of Analog Outputs
1
Number of Digital Outputs
1
Number of inputs and outputs
Number of digital outputs: 1; Number of analog outputs: 1
Operating Voltage (V)
18...32 DC
Operating voltage [V]
18...32 DC; (cULus - Class 2 source required)
Output Function
Normally Closed
Output Signal
analog signal; IO-Link
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
100
Permanent current rating of switching output DC [mA]
100
Power-on Delay Time (S)
6
Power-on delay time [s]
6
Precision Analog Output (K)
± 0, 2
Precision analog output [K]
± 0, 2
Precision IO-Link (K)
± 0, 2
Precision IO-Link [K]
± 0, 2
Probe Diameter (mm)
6
Probe diameter [mm]
6
Probe Length L (mm)
50
Probe length L [mm]
50
Process Connection
Threaded Connection G 1 / 2 External Thread Sealing Cone
Process data analog
1
Process data binary
1
Protection
IP 68; IP 69K
Protection Class
III
Reference Element
1 x NTC
Required master port class
A
Resolution of Analog Output (K)
0.05
Resolution of analog output [K]
0.05
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9 CDV
Short-circuit Protection
Yes
SIO mode
Yes
Special feature
Gold-plated contacts
Storage Temperature (°C)
-40...100
Storage temperature [°C]
-40...100
Surface Characteristics Ra/Rz of The Wetted Parts
Ra < 0.8 µm
Temperature Coefficient Analog Output (% of The Span / 10 K)
< ± 0, 02
Temperature Coefficient IO-Link (% of The Span / 10 K)
< ± 0, 01
Tightening Torque (Nm)
30...50
Tightening torque [Nm]
30...50
Total Number of Outputs
2
Transmission type
COM2 (38, 4 kBaud)
Type of Short-circuit Protection
Yes (Non-latching)
- Immediate notification of deviations in accuracy
- Improved quality assurance in between calibration intervals
- Robust design for permanently precise measurements even in demanding environments
- Transparent sensor monitoring thanks to logging of the diagnostic values
- Simulation function simplifies installation
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Berliss
Model
BSP-2002
Brand
Flowtrend
Model
1180000120
Brand
Walter
Model
48H310
Brand
Flowtrend
Model
2102723
Brand
Dodge
Model
232823
Brand
Drillco
Model
1000A207
Brand
SMC
Model
PSE310-B