Stop searching, install MROSupply Smart Check and see our price instantly wherever you browse.

Download Now

Add products to your shopping cart
Know When You’re Overpaying
The MROSupply Chrome Extension instantly alerts you when the part you’re viewing is available for less at MROSupply.
Download Now
We never track your browsing or search history
We never sell your data to third parties
TCC531

Image for Illustration purposes only. Actual product may vary

View in markdown

IFM TCC531 TCC100K1ER12-A-DKG/US Temperature transmitter

MODEL TCC531

BRAND

IFM

SKU

96946431

UOM

each

$555.50 Each

Prices are subject to change

FREE SHIPPING ON ORDERS OVER $100

Select Quantity

GET A QUOTE

Returnable: Yes

Ambient Temperature (°C)

-25...70

Ambient temperature [°C]

-25...70

Analog Current Output (Ma)

4...20

Analog current output [mA]

4...20

BLOB

Binary Large Object Transfer

Calibration Check Limit (K)

0.5...3

Calibration check limit [K]

0.5...3

Communication Interface

IO-Link

Connector

1 x M12; coding: A; Contacts: gold-plated

Current Consumption (Ma)

10

Current consumption [mA]

10; (24 V)

Diagnostic Output

Calibration Check Status and Error Diagnostics

Dimensions (mm)

Ø 50 / L = 194

Dimensions [mm]

Ø 50 / L = 194

Dynamic Response T05 / T09 (S)

1, 5 / 4

Dynamic response T05 / T09 [s]

1, 5 / 4

Electrical Design

PNP / NPN

Factory setting

14...302 °F

File Number UL

E217884

Housing

Tubular

In Steps of (K)

0.05

In steps of [K]

0.05

Installation Length EL (mm)

100

Installation length EL [mm]

100

Integrated Watchdog

Yes

IO-Link Resolution Temperature (K)

0.01

IO-Link resolution temperature [K]

0.01

IO-Link Revision

1.1

Material

stainless steel (1.4404 / 316L); PEI; FKM; PFA

Materials (Wetted Parts)

stainless steel (1.4404 / 316L); PEEK

Max. load [Ω]

(Ub - 15 V) x 50

Max. voltage drop switching output DC [V]

2

Maximum Load (Ω)

(Ub - 15 V) x 50

Maximum Voltage Drop Switching Output DC (V)

2

Measuring Element

1 x Pt 1000

Media

Liquids and Gases

Min. process cycle time [ms]

4.4

Minimum Installation Depth (mm)

15

Minimum installation depth [mm]

15

Minimum Process Cycle Time (Ms)

4.4

MTTF (Years)

329

MTTF [years]

329

Number of Analog Outputs

1

Number of Digital Outputs

1

Number of inputs and outputs

Number of digital outputs: 1; Number of analog outputs: 1

Operating Voltage (V)

18...32 DC

Operating voltage [V]

18...32 DC; (cULus - Class 2 source required)

Output Function

Normally Closed

Output Signal

analog signal; IO-Link

Overload Protection

Yes

Pack quantity

1 pcs.

Permanent Current Rating of Switching Output DC (Ma)

100

Permanent current rating of switching output DC [mA]

100

Power-on Delay Time (S)

6

Power-on delay time [s]

6

Precision Analog Output (K)

± 0, 2

Precision analog output [K]

± 0, 2

Precision IO-Link (K)

± 0, 2

Precision IO-Link [K]

± 0, 2

Probe Diameter (mm)

6

Probe diameter [mm]

6

Probe Length L (mm)

100

Probe length L [mm]

100

Process Connection

Threaded Connection G 1 / 2 External Thread Sealing Cone

Process data analog

1

Process data binary

1

Protection

IP 68; IP 69K

Protection Class

III

Reference Element

1 x NTC

Required master port class

A

Resolution of Analog Output (K)

0.05

Resolution of analog output [K]

0.05

Reverse Polarity Protection

Yes

SDCI Standard

IEC 61131-9 CDV

Short-circuit Protection

Yes

SIO mode

Yes

Special feature

Gold-plated contacts

Storage Temperature (°C)

-40...100

Storage temperature [°C]

-40...100

Surface Characteristics Ra/Rz of The Wetted Parts

Ra < 0.8 µm

Temperature Coefficient Analog Output (% of The Span / 10 K)

< ± 0, 02

Temperature Coefficient IO-Link (% of The Span / 10 K)

< ± 0, 01

Tightening Torque (Nm)

30...50

Tightening torque [Nm]

30...50

Total Number of Outputs

2

Transmission type

COM2 (38, 4 kBaud)

Type of Short-circuit Protection

Yes (Non-latching)

  • Immediate notification of deviations in accuracy
  • Improved quality assurance in between calibration intervals
  • Robust design for permanently precise measurements even in demanding environments
  • Transparent sensor monitoring thanks to logging of the diagnostic values
  • Simulation function simplifies installation

Aug. 15, 2019

PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.

Read More

 
Aug. 14, 2019

When selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.

Read More

 
Recently Viewed
MB58X3/4

#706942

Brand

Dodge

Model

MB58X3/4

$51.68 Each
Free Shipping orders over $100
5LK880

#2337360

Brand

MasterDrive

Model

5LK880

$49.17 Each
Free Shipping orders over $100
023519

#122759

Brand

Dodge

Model

023519

$1,079.78 Each Add to cart for a lower price
Free shipping
29507-3357

#5082709

Brand

Timken

Model

29507-3357

$978.62 Each
Free shipping
RSSS-300-4SP2

#5781005

Brand

Remke

Model

RSSS-300-4SP2

$213.91 Each
Free shipping
PT99311

#6302710

Brand

Starrett

Model

PT99311

$43.20 Each
Free Shipping orders over $100
75056301

#2813595

Brand

Dichtomatik

Model

75056301

$0.11 Each
Free Shipping orders over $100