TCC541

Image for Illustration purposes only. Actual product may vary

View in markdown

IFM TCC541 TCC150K1ER12-A-DKG/US Temperature transmitter

MODEL TCC541

BRAND

IFM

SKU

96946432

UOM

each

$561.66 Each

Prices are subject to change

FREE SHIPPING ON ORDERS OVER $100

Select Quantity

GET A QUOTE

Returnable: Yes

Ambient Temperature (°C)

-25...70

Ambient temperature [°C]

-25...70

Analog Current Output (Ma)

4...20

Analog current output [mA]

4...20

BLOB

Binary Large Object Transfer

Calibration Check Limit (K)

0.5...3

Calibration check limit [K]

0.5...3

Communication Interface

IO-Link

Connector

1 x M12; coding: A; Contacts: gold-plated

Current Consumption (Ma)

10

Current consumption [mA]

10; (24 V)

Diagnostic Output

Calibration Check Status and Error Diagnostics

Dimensions (mm)

Ø 50 / L = 244

Dimensions [mm]

Ø 50 / L = 244

Dynamic Response T05 / T09 (S)

1, 5 / 4

Dynamic response T05 / T09 [s]

1, 5 / 4

Electrical Design

PNP / NPN

Factory setting

14...302 °F

File Number UL

E217884

Housing

Tubular

In Steps of (K)

0.05

In steps of [K]

0.05

Installation Length EL (mm)

150

Installation length EL [mm]

150

Integrated Watchdog

Yes

IO-Link Resolution Temperature (K)

0.01

IO-Link resolution temperature [K]

0.01

IO-Link Revision

1.1

Material

stainless steel (1.4404 / 316L); PEI; FKM; PFA

Materials (Wetted Parts)

stainless steel (1.4404 / 316L); PEEK

Max. load [Ω]

(Ub - 15 V) x 50

Max. voltage drop switching output DC [V]

2

Maximum Load (Ω)

(Ub - 15 V) x 50

Maximum Voltage Drop Switching Output DC (V)

2

Measuring Element

1 x Pt 1000

Media

Liquids and Gases

Min. process cycle time [ms]

4.4

Minimum Installation Depth (mm)

15

Minimum installation depth [mm]

15

Minimum Process Cycle Time (Ms)

4.4

MTTF (Years)

329

MTTF [years]

329

Number of Analog Outputs

1

Number of Digital Outputs

1

Number of inputs and outputs

Number of digital outputs: 1; Number of analog outputs: 1

Operating Voltage (V)

18...32 DC

Operating voltage [V]

18...32 DC; (cULus - Class 2 source required)

Output Function

Normally Closed

Output Signal

analog signal; IO-Link

Overload Protection

Yes

Pack quantity

1 pcs.

Permanent Current Rating of Switching Output DC (Ma)

100

Permanent current rating of switching output DC [mA]

100

Power-on Delay Time (S)

6

Power-on delay time [s]

6

Precision Analog Output (K)

± 0, 2

Precision analog output [K]

± 0, 2

Precision IO-Link (K)

± 0, 2

Precision IO-Link [K]

± 0, 2

Probe Diameter (mm)

6

Probe diameter [mm]

6

Probe Length L (mm)

150

Probe length L [mm]

150

Process Connection

Threaded Connection G 1 / 2 External Thread Sealing Cone

Process data analog

1

Process data binary

1

Protection

IP 68; IP 69K

Protection Class

III

Reference Element

1 x NTC

Required master port class

A

Resolution of Analog Output (K)

0.05

Resolution of analog output [K]

0.05

Reverse Polarity Protection

Yes

SDCI Standard

IEC 61131-9 CDV

Short-circuit Protection

Yes

SIO mode

Yes

Special feature

Gold-plated contacts

Storage Temperature (°C)

-40...100

Storage temperature [°C]

-40...100

Surface Characteristics Ra/Rz of The Wetted Parts

Ra < 0.8 µm

Temperature Coefficient Analog Output (% of The Span / 10 K)

< ± 0, 02

Temperature Coefficient IO-Link (% of The Span / 10 K)

< ± 0, 01

Tightening Torque (Nm)

30...50

Tightening torque [Nm]

30...50

Total Number of Outputs

2

Transmission type

COM2 (38, 4 kBaud)

Type of Short-circuit Protection

Yes (Non-latching)

  • Immediate notification of deviations in accuracy
  • Improved quality assurance in between calibration intervals
  • Robust design for permanently precise measurements even in demanding environments
  • Transparent sensor monitoring thanks to logging of the diagnostic values
  • Simulation function simplifies installation

Aug. 15, 2019

PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.

Read More

 
Aug. 14, 2019

When selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.

Read More

 
Recently Viewed
41705033008

#97184102

Brand

FEIN

Model

41705033008

$16.26 Each
Free Shipping orders over $100
209861

#96675248

Brand

Dodge

Model

209861

$710.83 Each
Free shipping
295454

#96670729

Brand

Dodge

Model

295454

$1,650.50 Each
Free shipping
071721

#786304

Brand

Dodge

Model

071721

$3,603.63 Each Add to cart for a lower price
Free shipping
T10-950-12

#1251553

Brand

Gates Rubber

Model

T10-950-12

Call for pricing
705-52

#1960852

Brand

Champion

Model

705-52

$1.31 Each