We never sell your data to third parties
IFM UGT304 UGA401000R1KG/AM/IO/US Full-metal ultrasonic sensor
MODEL UGT304
$536.36 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Ambient Temperature (°C)
-20...70
Ambient temperature [°C]
-20...70
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20
Angle of Aperture Cylindrical (°)
16
Angle of aperture cylindrical [°]
16; (±1)
Binary Switching Information
2
Blind Zone (mm)
100
Blind zone [mm]
100
Communication Interface
IO-Link
Connector
1 x M12; coding: A; Contacts: 4
Converter Frequency (Khz)
200
Converter frequency [kHz]
200
Current Consumption (Ma)
< 50
Current consumption [mA]
< 50
Device Status
4
Dimensions (mm)
M18 x 1 / L = 98.5
Dimensions [mm]
M18 x 1 / L = 98.5
Electrical Design
PNP / NPN
Enclosure Type
Type 1
File Number UL
E174191
Housing
Threaded Type
Hysteresis (%)
< 1
Hysteresis [%]
< 1
IO-Link Functions (Acyclical)
Application Specific Tag; Operating Hours Counter
IO-Link Revision
1.1
Linearity Error of Analog Output (%)
1
Linearity error of analog output [%]
1; (of the final value of the measuring range)
Material
housing: stainless steel (1.4404 / 316L); LED window: PA
Max. deviation from the 90° angle sensor/object [°]
± 4
Max. load [Ω]
500
Max. voltage drop switching output DC [V]
2.2
Maximum Deviation From The 90° Angle Sensor/Object (°)
± 4
Maximum Load (Ω)
500
Maximum Voltage Drop Switching Output DC (V)
2.2
Min. process cycle time [ms]
3.2
Minimum Process Cycle Time (Ms)
3.2
MTTF (Years)
838
MTTF [years]
838
Notes On The Accuracy / Deviation
The Indicated Values Are Reached After A Warm-up Time of Min. 20 Minutes
Number of Analog Outputs
1
Number of Digital Outputs
1
Number of inputs and outputs
Number of digital outputs: 1; Number of analog outputs: 1
Operating Voltage (V)
10...30 DC
Operating voltage [V]
10...30 DC; (cULus - Class 2 source required)
Output Function
Normally Open / Closed
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
100
Permanent current rating of switching output DC [mA]
100
Power-on Delay Time (S)
< 0.5
Power-on delay time [s]
< 0.5
Process Value
16
Protection
IP 65; IP 67; IP 68; IP 69K
Protection Class
III
Repeatability
0, 5 %
Required master port class
A
Resolution (mm)
1
Resolution [mm]
1
Response Time (Ms)
< 600
Response time [ms]
< 600; (analog output)
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9
Sensing Range (mm)
100...1000
Sensing range [mm]
100...1000; (Target: 100 x 100 mm)
Short-circuit Protection
Yes
SIO mode
Yes
Storage Temperature (°C)
-25...75
Storage temperature [°C]
-25...75
Switching Frequency DC (Hz)
6
Switching frequency DC [Hz]
6
Switching Status
1 LED, yellow
Ta
-20...70 °C
Temperature Compensation
Yes
Temperature Drift
± 2 %
Thread Designation
M18 X 1
Tightening Torque (Nm)
50
Tightening torque [Nm]
50
Total Number of Outputs
2
Transmission type
COM2 (38, 4 kBaud)
Voltage Supply
Class 2
- Continuous level and object detection for harsh environments
- Resistant to aggressive media
- Long range
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Thomson Linear
Model
511U15E1G2
Brand
Dodge
Model
233511
Brand
Thomson Linear
Model
511H25D1NG1
Brand
IFM
Model
IM5044
Brand
Dodge
Model
295192
Brand
Goulds
Model
3SV15NB8F60
Brand
Thomson Linear
Model
SRT0606
Brand
Pramet
Model
OZ32.C.32.P