UGT305

Image for Illustration purposes only. Actual product may vary

View in markdown

IFM UGT305 UGA401000R2KG/AM/IO/US Full-metal ultrasonic sensor

MODEL UGT305

BRAND

IFM

SKU

96946529

UOM

each

$536.36 Each

Prices are subject to change

FREE SHIPPING ON ORDERS OVER $100

Select Quantity

GET A QUOTE

Returnable: Yes

Ambient Temperature (°C)

-20...70

Ambient temperature [°C]

-20...70

Analog Voltage Output (V)

0...10

Analog voltage output [V]

0...10

Angle of Aperture Cylindrical (°)

16

Angle of aperture cylindrical [°]

16; (±1)

Binary Switching Information

2

Blind Zone (mm)

100

Blind zone [mm]

100

Communication Interface

IO-Link

Connector

1 x M12; coding: A; Contacts: 4

Converter Frequency (Khz)

200

Converter frequency [kHz]

200

Current Consumption (Ma)

< 50

Current consumption [mA]

< 50

Device Status

4

Dimensions (mm)

M18 x 1 / L = 98.5

Dimensions [mm]

M18 x 1 / L = 98.5

Electrical Design

PNP / NPN

Enclosure Type

Type 1

File Number UL

E174191

Housing

Threaded Type

Hysteresis (%)

< 1

Hysteresis [%]

< 1

IO-Link Functions (Acyclical)

Application Specific Tag; Operating Hours Counter

IO-Link Revision

1.1

Linearity Error of Analog Output (%)

1

Linearity error of analog output [%]

1; (of the final value of the measuring range)

Material

housing: stainless steel (1.4404 / 316L); LED window: PA

Max. deviation from the 90° angle sensor/object [°]

± 4

Max. voltage drop switching output DC [V]

2.2

Maximum Deviation From The 90° Angle Sensor/Object (°)

± 4

Maximum Voltage Drop Switching Output DC (V)

2.2

Min. load resistance [Ω]

3000

Min. process cycle time [ms]

3.2

Minimum Load Resistance (Ω)

3000

Minimum Process Cycle Time (Ms)

3.2

MTTF (Years)

838

MTTF [years]

838

Notes On The Accuracy / Deviation

The Indicated Values Are Reached After A Warm-up Time of Min. 20 Minutes

Number of Analog Outputs

1

Number of Digital Outputs

1

Number of inputs and outputs

Number of digital outputs: 1; Number of analog outputs: 1

Operating Voltage (V)

10...30 DC

Operating voltage [V]

10...30 DC; (cULus - Class 2 source required)

Output Function

Normally Open / Closed

Overload Protection

Yes

Pack quantity

1 pcs.

Permanent Current Rating of Switching Output DC (Ma)

100

Permanent current rating of switching output DC [mA]

100

Power-on Delay Time (S)

< 0.5

Power-on delay time [s]

< 0.5

Process Value

16

Protection

IP 65; IP 67; IP 68; IP 69K

Protection Class

III

Repeatability

0, 5 %

Required master port class

A

Resolution (mm)

1

Resolution [mm]

1

Response Time (Ms)

< 600

Response time [ms]

< 600; (analog output)

Reverse Polarity Protection

Yes

SDCI Standard

IEC 61131-9

Sensing Range (mm)

100...1000

Sensing range [mm]

100...1000; (Target: 100 x 100 mm)

Short-circuit Protection

Yes

SIO mode

Yes

Storage Temperature (°C)

-25...75

Storage temperature [°C]

-25...75

Switching Frequency DC (Hz)

6

Switching frequency DC [Hz]

6

Switching Status

1 LED, yellow

Ta

-20...70 °C

Temperature Compensation

Yes

Temperature Drift

± 2 %

Thread Designation

M18 X 1

Tightening Torque (Nm)

50

Tightening torque [Nm]

50

Total Number of Outputs

2

Transmission type

COM2 (38, 4 kBaud)

Voltage Supply

Class 2

  • Continuous level and object detection for harsh environments
  • Resistant to aggressive media
  • Long range

Aug. 15, 2019

PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.

Read More

 
Aug. 14, 2019

When selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.

Read More

 
Recently Viewed
31345079010

#97181583

Brand

FEIN

Model

31345079010

$22.54 Each
Free Shipping orders over $100
TB50N008F2

#96818304

Brand

ACME

Model

TB50N008F2

$81.83 Each
Free Shipping orders over $100
766483

#2275742

Brand

Browning

Model

766483

$397.60 Each
Free shipping
065299

#122867

Brand

Dodge

Model

065299

$14,001.40 Each Add to cart for a lower price
Free shipping
14020

#6295259

Brand

Te-Co

Model

14020

$25.15 Each
Free Shipping orders over $100
NU2248EMA

#5117782

Brand

Timken

Model

NU2248EMA

$13,129.61 Each
Free shipping