IFM UGT511 UGA01600E2KG/IO-LINK/US Ultrasonic sensor

MODEL UGT511

BRAND

IFM

SKU

96946541

UOM

each

$315.37 Each

Prices are subject to change

FREE SHIPPING ON ORDERS OVER $100

Select Quantity

GET A QUOTE

Returnable: Yes

Ambient Temperature (°C)

-20...70

Ambient temperature [°C]

-20...70

Analog Voltage Output (V)

0...10

Analog voltage output [V]

0...10

Angle of Aperture Cylindrical (°)

15

Angle of aperture cylindrical [°]

15; (±2)

Binary Switching Information

2

Blind Zone (mm)

150

Blind zone [mm]

150

Communication Interface

IO-Link

Connector

1 x M12; coding: A

Converter Frequency (Khz)

230

Converter frequency [kHz]

230

Current Consumption (Ma)

55

Current consumption [mA]

55

Device Status

4

Dimensions (mm)

M18 x 1 / L = 97.5

Dimensions [mm]

M18 x 1 / L = 97.5

Echo

1 x LED, green

Electrical Design

PNP

File Number UL

E174191

Housing

Threaded Type

Hysteresis (%)

< 2

Hysteresis [%]

< 2

IO-Link Functions (Acyclical)

Application Specific Tag; Operating Hours Counter

IO-Link Revision

1.1

Linearity Error of Analog Output (%)

<2

Linearity error of analog output [%]

<2

Material

stainless steel (1.4404 / 316L); PA; epoxy glass ceramics

Max. deviation from the 90° angle sensor/object [°]

± 4

Max. voltage drop switching output DC [V]

2.2

Maximum Deviation From The 90° Angle Sensor/Object (°)

± 4

Maximum Voltage Drop Switching Output DC (V)

2.2

Min. load resistance [Ω]

3000

Min. process cycle time [ms]

3.2

Minimum Load Resistance (Ω)

3000

Minimum Process Cycle Time (Ms)

3.2

MTTF (Years)

125

MTTF [years]

125

Notes On The Accuracy / Deviation

The Indicated Values Are Reached After A Warm-up Time of Min. 20 Minutes

Number of Analog Outputs

1

Number of Digital Outputs

1

Number of inputs and outputs

Number of digital outputs: 1; Number of analog outputs: 1

Operating Voltage (V)

10...30 DC

Operating voltage [V]

10...30 DC; (cULus - Class 2 source required)

Output Function

Normally Open / Closed

Output Signal

switching signal; analog signal; IO-Link

Overload Protection

Yes

Pack quantity

1 pcs.

Permanent Current Rating of Switching Output DC (Ma)

100

Permanent current rating of switching output DC [mA]

100

Power-on Delay Time (S)

< 0.3

Power-on delay time [s]

< 0.3

Process Value

16

Protection

IP 67

Protection Class

III

Repeatability

1 %

Required master port class

A

Resolution of Analog Output

< 3 mm

Response Time (Ms)

< 300

Response time [ms]

< 300; (analog output)

Reverse Polarity Protection

Yes

SDCI Standard

IEC 61131-9

Sensing Range (mm)

150...1600

Sensing range [mm]

150...1600; (Target: 200 x 200 mm)

Short-circuit Protection

Yes

SIO mode

Yes

Storage Temperature (°C)

-30...80

Storage temperature [°C]

-30...80

Switch-point Drift (%)

-2...2

Switch-point drift [%]

-2...2

Switching Frequency DC (Hz)

3

Switching frequency DC [Hz]

3

Switching Status

2 x LED, yellow

Ta

-20...70 °C

Teach Function

Yes

Temperature Compensation

Yes

Thread Designation

M18 X 1

Tightening Torque (Nm)

50

Tightening torque [Nm]

50

Total Number of Outputs

2

Transmission type

COM2 (38, 4 kBaud)

Voltage Supply

Class 2

  • Very large detection range
  • Intuitive setting of the detection range via pushbutton or IO-Link
  • Clearly visible LED for indicating switching status and echo
  • With programmable switching output and scalable analog output
  • Non-contact detection independent of color, transparency or surface characteristics of the object

Aug. 15, 2019

PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.

Read More

 
Aug. 14, 2019

When selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.

Read More

 
Recently Viewed
23164EMBW509C08C3

#5118853

Brand

Timken

Model

23164EMBW509C08C3

$24,572.81 Each
Free shipping
445815-NIST

#97206527

Brand

Extech

Model

445815-NIST

$154.00 Each
Free shipping
40B34FL

#397528

Brand

U.S.Tsubaki

Model

40B34FL

$66.95 Each
Free Shipping orders over $100
012003

#97212759

Brand

Walter

Model

012003

$2.33 Each
Free Shipping orders over $100
40A46

#395701

Brand

U.S.Tsubaki

Model

40A46

$33.20 Each
Free Shipping orders over $100
LF3873-K7.5

#521353

Brand

Rexnord

Model

LF3873-K7.5

Call for pricing
B87328

#96752186

Brand

Berkeley

Model

B87328

$9,622.94 Each
Free shipping