Stop searching, install MROSupply Smart Check and see our price instantly wherever you browse.

Download Now

Add products to your shopping cart
Know When You’re Overpaying
The MROSupply Chrome Extension instantly alerts you when the part you’re viewing is available for less at MROSupply.
Download Now
We never track your browsing or search history
We never sell your data to third parties
UGT514

Image for Illustration purposes only. Actual product may vary

View in markdown

IFM UGT514 UGA02200E2KG/IO-LINK/US Ultrasonic sensor

MODEL UGT514

BRAND

IFM

SKU

96946544

UOM

each

$315.37 Each

Prices are subject to change

FREE SHIPPING ON ORDERS OVER $100

Select Quantity

GET A QUOTE

Returnable: Yes

Ambient Temperature (°C)

-20...70

Ambient temperature [°C]

-20...70

Analog Voltage Output (V)

0...10

Analog voltage output [V]

0...10

Angle of Aperture Cylindrical (°)

14

Angle of aperture cylindrical [°]

14; (±2)

Binary Switching Information

2

Blind Zone (mm)

200

Blind zone [mm]

200

Communication Interface

IO-Link

Connector

1 x M12; coding: A

Converter Frequency (Khz)

200

Converter frequency [kHz]

200

Current Consumption (Ma)

55

Current consumption [mA]

55

Device Status

4

Dimensions (mm)

M18 x 1 / L = 97.5

Dimensions [mm]

M18 x 1 / L = 97.5

Echo

1 x LED, green

Electrical Design

PNP

File Number UL

E174191

Housing

Threaded Type

Hysteresis (%)

< 2

Hysteresis [%]

< 2

IO-Link Functions (Acyclical)

Application Specific Tag; Operating Hours Counter

IO-Link Revision

1.1

Linearity Error of Analog Output (%)

<3

Linearity error of analog output [%]

<3

Material

stainless steel (1.4404 / 316L); PA; epoxy glass ceramics

Max. deviation from the 90° angle sensor/object [°]

± 4

Max. voltage drop switching output DC [V]

2.2

Maximum Deviation From The 90° Angle Sensor/Object (°)

± 4

Maximum Voltage Drop Switching Output DC (V)

2.2

Min. load resistance [Ω]

3000

Min. process cycle time [ms]

3.2

Minimum Load Resistance (Ω)

3000

Minimum Process Cycle Time (Ms)

3.2

MTTF (Years)

142

MTTF [years]

142

Notes On The Accuracy / Deviation

The Indicated Values Are Reached After A Warm-up Time of Min. 20 Minutes

Number of Analog Outputs

1

Number of Digital Outputs

1

Number of inputs and outputs

Number of digital outputs: 1; Number of analog outputs: 1

Operating Voltage (V)

10...30 DC

Operating voltage [V]

10...30 DC; (cULus - Class 2 source required)

Output Function

Normally Open / Closed

Output Signal

switching signal; analog signal; IO-Link

Overload Protection

Yes

Pack quantity

1 pcs.

Permanent Current Rating of Switching Output DC (Ma)

100

Permanent current rating of switching output DC [mA]

100

Power-on Delay Time (S)

< 0.3

Power-on delay time [s]

< 0.3

Process Value

16

Protection

IP 67

Protection Class

III

Repeatability

1 %

Required master port class

A

Resolution of Analog Output

< 3 mm

Response Time (Ms)

< 400

Response time [ms]

< 400; (analog output)

Reverse Polarity Protection

Yes

SDCI Standard

IEC 61131-9

Sensing Range (mm)

200...2200

Sensing range [mm]

200...2200; (Target: 200 x 200 mm)

Short-circuit Protection

Yes

SIO mode

Yes

Storage Temperature (°C)

-30...80

Storage temperature [°C]

-30...80

Switch-point Drift (%)

-2...2

Switch-point drift [%]

-2...2

Switching Frequency DC (Hz)

2

Switching frequency DC [Hz]

2

Switching Status

2 x LED, yellow

Ta

-20...70 °C

Teach Function

Yes

Temperature Compensation

Yes

Thread Designation

M18 X 1

Tightening Torque (Nm)

50

Tightening torque [Nm]

50

Total Number of Outputs

2

Transmission type

COM2 (38, 4 kBaud)

Voltage Supply

Class 2

  • Very large detection range
  • Intuitive setting of the detection range via pushbutton or IO-Link
  • Clearly visible LED for indicating switching status and echo
  • With programmable switching output and scalable analog output
  • Non-contact detection independent of color, transparency or surface characteristics of the object

Aug. 15, 2019

PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.

Read More

 
Aug. 14, 2019

When selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.

Read More

 
Recently Viewed
455878

#137059

Brand

Dodge

Model

455878

$513.74 Each Add to cart for a lower price
Free shipping
HMV 52

#5120845

Brand

Timken

Model

HMV 52

$4,704.28 Each
Free shipping
077217

#1291133

Brand

Dodge

Model

077217

$3,066.38 Each Add to cart for a lower price
Free shipping
1004670

#2286999

Brand

Browning

Model

1004670

$224.32 Each
Free shipping
293252

#96656053

Brand

Dodge

Model

293252

$3,906.50 Each
Free shipping
BVMX3-2-700

#96753751

Brand

Berkeley

Model

BVMX3-2-700

$1,846.47 Each
Free shipping
AL2340

#96943428

Brand

IFM

Model

AL2340

$195.25 Each
Free shipping