We never sell your data to third parties
$236.28 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Ambient Temperature (°C)
-20...70
Ambient temperature [°C]
-20...70
Angle of Aperture Cylindrical (°)
15
Angle of aperture cylindrical [°]
15; (±2)
Binary Switching Information
2
Blind Zone (mm)
40
Blind zone [mm]
40
Communication Interface
IO-Link
Connector
1 x M12; coding: A
Converter Frequency (Khz)
300
Converter frequency [kHz]
300
Current Consumption (Ma)
< 35
Current consumption [mA]
< 35
Device Status
4
Dimensions (mm)
M18 x 1 / L = 60.5
Dimensions [mm]
M18 x 1 / L = 60.5
Echo
1 x LED, green
Electrical Design
PNP
File Number UL
E174191
Housing
Threaded Type
Hysteresis (%)
< 1
Hysteresis [%]
< 1
IO-Link Functions (Acyclical)
Application Specific Tag; Operating Hours Counter
IO-Link Revision
1.1
Material
stainless steel (1.4404 / 316L); PA; epoxy glass ceramics
Max. deviation from the 90° angle sensor/object [°]
± 4
Max. voltage drop switching output DC [V]
2.2
Maximum Deviation From The 90° Angle Sensor/Object (°)
± 4
Maximum Voltage Drop Switching Output DC (V)
2.2
Min. process cycle time [ms]
3.2
Minimum Process Cycle Time (Ms)
3.2
MTTF (Years)
202
MTTF [years]
202
Notes On The Accuracy / Deviation
The Indicated Values Are Reached After A Warm-up Time of Min. 20 Minutes
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2
Operating Voltage (V)
10...30 DC
Operating voltage [V]
10...30 DC; (cULus - Class 2 source required)
Output Function
Normally Open / Closed
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
100
Permanent current rating of switching output DC [mA]
100
Power-on Delay Time (S)
< 0.3
Power-on delay time [s]
< 0.3
Process Value
16
Protection
IP 67
Protection Class
III
Repeatability
<0, 7 %
Required master port class
A
Resolution (mm)
1
Resolution [mm]
1
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9
Sensing Range (mm)
40...300
Sensing range [mm]
40...300; (Target: 200 x 200 mm)
Short-circuit Protection
Yes
SIO mode
Yes
Storage Temperature (°C)
-30...80
Storage temperature [°C]
-30...80
Switch-point Drift (%)
-2...2
Switch-point drift [%]
-2...2
Switching Frequency DC (Hz)
8
Switching frequency DC [Hz]
8
Switching Status
2 x LED, yellow
Ta
-20...70 °C
Temperature Compensation
Yes
Thread Designation
M18 X 1
Tightening Torque (Nm)
50
Tightening torque [Nm]
50
Total Number of Outputs
2
Transmission type
COM2 (38, 4 kBaud)
Voltage Supply
Class 2
- Output function normally open / normally closed programmable
- Clearly visible LED for indicating switching status and echo
- Non-contact detection independent of color, transparency or surface characteristics of the object
- Particularly space-saving design for use where space is restricted
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Dodge
Model
219942
Brand
Thomson Linear
Model
411H30E0D
Brand
Schunk
Model
432349
Brand
Drillco
Model
280A022
Brand
FEIN
Model
39000000664
Brand
Walter
Model
6985
Brand
Flowtrend
Model
2141717