Returnable: Yes
Ambient Temperature (°C)
-20...70
Ambient temperature [°C]
-20...70
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20
Angle of Aperture Cylindrical (°)
14
Angle of aperture cylindrical [°]
14; (±2)
Blind Zone (mm)
80
Blind zone [mm]
80
Connector
1 x M12; coding: A
Converter Frequency (Khz)
200
Converter frequency [kHz]
200
Current Consumption (Ma)
< 35
Current consumption [mA]
< 35
Dimensions (mm)
53 x 20 x 37.7
Dimensions [mm]
53 x 20 x 37.7
Echo
1 x LED, green
Electrical Design
NPN
File Number UL
E174191
Housing
Rectangular With M18 Thread
Hysteresis (%)
< 1
Hysteresis [%]
< 1
Linearity Error of Analog Output (%)
≤ 1
Linearity error of analog output [%]
≤ 1
Material
stainless steel (630 / 1.4542 / 17-4 PH); PBT; PA; epoxy glass ceramics
Max. deviation from the 90° angle sensor/object [°]
± 4
Max. load [Ω]
500
Max. voltage drop switching output DC [V]
2.2
Maximum Deviation From The 90° Angle Sensor/Object (°)
± 4
Maximum Load (Ω)
500
Maximum Voltage Drop Switching Output DC (V)
2.2
MTTF (Years)
190
MTTF [years]
190
Notes On The Accuracy / Deviation
The Indicated Values Are Reached After A Warm-up Time of Min. 20 Minutes
Number of Analog Outputs
1
Number of Digital Outputs
1
Number of inputs and outputs
Number of digital outputs: 1; Number of analog outputs: 1
Operating Voltage (V)
10...30 DC
Operating voltage [V]
10...30 DC; (cULus - Class 2 source required)
Output Function
Normally Open / Closed
Output Signal
Switching Signal; Analog Signal
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
100
Permanent current rating of switching output DC [mA]
100
Power-on Delay Time (S)
< 0.3
Power-on delay time [s]
< 0.3
Protection
IP 67
Protection Class
III
Repeatability
1 %
Resolution (mm)
3
Resolution [mm]
3
Response Time (Ms)
< 450
Response time [ms]
< 450; (analog output)
Reverse Polarity Protection
Yes
Sensing Range (mm)
80...1200
Sensing range [mm]
80...1200; (Target: 200 x 200 mm)
Short-circuit Protection
Yes
Storage Temperature (°C)
-30...80
Storage temperature [°C]
-30...80
Switch-point Drift (%)
-5...5
Switch-point drift [%]
-5...5
Switching Frequency DC (Hz)
5
Switching frequency DC [Hz]
5
Switching Status
1 x LED, yellow
Ta
-20...70 °C
Teach Function
Yes
Temperature Compensation
Yes
Thread Designation
M18 X 1
Tightening Torque (Nm)
50
Tightening torque [Nm]
50
Total Number of Outputs
2
Voltage Supply
Class 2
- Robust rectangular metal housing with M18 thread on the side
- Particularly space-saving design for use where space is restricted
- With programmable switching output and scalable analog output
- Non-contact detection independent of color, transparency or surface characteristics of the object
- Intuitive setting of the detection range via pushbutton
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Remke
Model
LNSS-150
Brand
Drillco
Model
20N116FB
Brand
Pramet
Model
7977570
Brand
Dodge
Model
298527
Brand
Dodge
Model
F2B-GT-45M-HTS
Brand
Dodge
Model
219865