We never sell your data to third parties
$261.58 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Ambient Temperature (°C)
-20...70
Ambient temperature [°C]
-20...70
Angle of Aperture Cylindrical (°)
15
Angle of aperture cylindrical [°]
15; (±2)
Binary Switching Information
2
Blind Zone (mm)
60
Blind zone [mm]
60
Communication Interface
IO-Link
Connector
1 x M12; coding: A
Converter Frequency (Khz)
230
Converter frequency [kHz]
230
Current Consumption (Ma)
< 35
Current consumption [mA]
< 35
Device Status
4
Dimensions (mm)
53 x 20 x 37.7
Dimensions [mm]
53 x 20 x 37.7
Echo
1 x LED, green
Electrical Design
PNP
File Number UL
E174191
Housing
Rectangular With M18 Thread
Hysteresis (%)
< 1
Hysteresis [%]
< 1
IO-Link Functions (Acyclical)
Application Specific Tag; Operating Hours Counter
IO-Link Revision
1.1
Material
stainless steel (630 / 1.4542 / 17-4 PH); PBT; PA; epoxy glass ceramics
Max. deviation from the 90° angle sensor/object [°]
± 4
Max. voltage drop switching output DC [V]
2.2
Maximum Deviation From The 90° Angle Sensor/Object (°)
± 4
Maximum Voltage Drop Switching Output DC (V)
2.2
Min. process cycle time [ms]
10
Minimum Process Cycle Time (Ms)
10
MTTF (Years)
201
MTTF [years]
201
Notes On The Accuracy / Deviation
The Indicated Values Are Reached After A Warm-up Time of Min. 20 Minutes
Number of Digital Outputs
1
Number of inputs and outputs
Number of digital outputs: 1
Operating Voltage (V)
10...30 DC
Operating voltage [V]
10...30 DC; (cULus - Class 2 source required)
Output Function
Normally Open / Closed
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
100
Permanent current rating of switching output DC [mA]
100
Power-on Delay Time (S)
< 0.3
Power-on delay time [s]
< 0.3
Process Value
16
Protection
IP 67
Protection Class
III
Repeatability
1 %
Repeatability IO-Link (%)
< 0, 7
Repeatability IO-Link [%]
< 0, 7
Required master port class
A
Resolution (mm)
1
Resolution [mm]
1
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9
Sensing Range (mm)
60...800
Sensing range [mm]
60...800; (Target: 100 x 100 mm)
Short-circuit Protection
Yes
SIO mode
Yes
Storage Temperature (°C)
-30...80
Storage temperature [°C]
-30...80
Switch-point Drift (%)
-2...2
Switch-point drift [%]
-2...2
Switching Frequency DC (Hz)
5
Switching frequency DC [Hz]
5
Switching Status
1 x LED, yellow
Ta
-20...70 °C
Teach Function
Yes
Temperature Compensation
Yes
Thread Designation
M18 X 1
Tightening Torque (Nm)
50
Tightening torque [Nm]
50
Total Number of Outputs
1
Transmission type
COM2 (38, 4 kBaud)
Voltage Supply
Class 2
- Robust rectangular metal housing with M18 thread on the side
- Particularly space-saving design for use where space is restricted
- Non-contact detection independent of color, transparency or surface characteristics of the object
- Intuitive setting of the detection range via pushbutton
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Thomson Linear
Model
MTS6210
Brand
Drillco
Model
700A512
Brand
Walter
Model
30B005
Brand
ABB
Model
PFVK104
Brand
Remke
Model
405A0050AK
Brand
Flowtrend
Model
107974
Brand
Thomson Linear
Model
511H35B2ES3