We never sell your data to third parties
Enerpac PAM-1042 100507 10 Series Air Pump VM4 Valve
MODEL PAM-1042
Contact supplier for technical support on: 800-558-0530 opt.2
Call for Pricing - 888-671-2883
Returnable:No
Brand
Enerpac
Model
HCRL-506
Brand
Enerpac
Model
ZU4420JB
Brand
Enerpac
Model
ZE2408EB
Brand
Enerpac
Model
PAM-1042
Air Consumption Lm (in)
510
Air consumption scfm
18
Air pressure range (Psi)
60 - 120
Cylinder compatability
Double-acting
Max flow at rated pressure imperial
9 in3/min
Max operating pressure (psi)
10,000
Maximum Flow Rate Ranges at Rated Pressure (in3/min)
0 - 20
Output flow rate 1st stage (in3 min)
650
Output flow rate 2nd stage (in3 min)
9
Pump power source
Air
Pump valve type
4-way, 3-position
Reservoir capacity (in3)
462
Reservoir Size Ranges Liters
8, 0 - 19, 9
Sound leveld (Ba)
87
Usable oilcapacity gal
2
Valve function
Advance / hold / retract
Valve model
VM4
Valve operation
Manual
Model: PAM1042 | ECCN:EAR99 | Harmonization:8413500080
Series: PAM | Product Line: Industrial Tools
- Twin air motor configuration delivers high-flow performance in first stage, up to 200 psi, for rapid cylinder advance
- 1 and 2 gallon reservoirs for use with a wide range of cylinders
- Integral shroud protects air motors and provides easy portability
No questions match your search.
Are all Enerpac hydraulic pumps rated for 10,000 psi? This product
No, so check the rating before you connect a pump to a cylinder or tool. Most Enerpac hand pumps, such as the P392, P80 and P842, the ZU and ZE electric pumps and the Turbo II PATG, PAMG and PARG air pumps run at 10,000 psi (700 bar). Some are lower: the P25 hand pump is rated 2,500 psi, the P51 3,000 psi and the P50 5,000 psi, and the ZW electric pumps and PACG air pumps built for workholding are 5,000 psi (350 bar). Turbo II air pumps come in 700 or 350 bar versions, so check the model. Others go higher: the HPT1500 hand pump and the ZUTP1500 and ATP1500 tensioner pumps deliver 1,500 bar (21,750 psi), and the HPN2000 hand pump is rated 2,000 bar. Every hose, gauge and cylinder on the pump must be rated for its pressure.
How do I decode an Enerpac Z-Class pump number such as ZU4308MB? This product
Enerpac's ordering guide reads the number position by position. Z is the pump class, then the motor: U universal electric, E induction electric, A air. Next is the flow group (4 is 60 in3/min), then the valve type: 1 dump VE32D, 2 three-way two-position VM32, 3 three-way three-position VM33, 4 four-way three-position VM43. Two digits give the reservoir (04 to 40), then valve operation: M manual, L manual with LCD, J or P with pendant, S solenoid, D dump. The last letter is the voltage, B for 115 V. ZU4308MB is therefore a ZU4, VM33 manual valve, 8 litre reservoir, 115 V. For other voltage letters, or to choose a pump, Enerpac asks you to send the complete model number to its technical services team.
How do I match an Enerpac pump to my cylinder? This product
Start with oil volume and valve type. A cylinder's oil capacity is its effective area times its stroke, and Enerpac says the pump's usable oil capacity should be greater than the total oil capacity of all the cylinders and hoses it feeds. A P392 hand pump, for example, has 55 cubic inches of usable oil. Single-acting cylinders need a pump with a 3-way valve and one hose; double-acting cylinders need a 4-way valve and two hoses, so for double-acting tools Enerpac points you to the P842 rather than the P392. Finally, the pump, hose and cylinder must all be rated for the same pressure.
What oil should I use in an Enerpac pump, and how do I top it up? This product
Enerpac sells two oils and says not to swap them. HF oil (HF-101 in 1 gallon, HF-102 in 5 gallons) is formulated for powered pumps and is not for use in hand pumps; LX oil (LX-101) is for hand pumps and not for power pumps. XC cordless pumps take Enerpac HF oil only, and for MP multi-fluid hand pumps Enerpac's technical services team advises on other fluids. Use only Enerpac oil to protect the warranty. Add oil only with the cylinders fully retracted (extended for pull cylinders), otherwise the system will hold more oil than the reservoir can take, and fill only to the level mark on the pump. Non-vented hand pumps need some air in the reservoir to work. For hand pumps Enerpac says to drain and refill with clean oil every 12 months, more often in dirty conditions.
What do Enerpac cylinder and pump set numbers like SCR1010H mean? This product
The set number names the cylinder and the pump. SCR sets use an RC cylinder, SCH an RCH hollow cylinder, SCL an RCS low height cylinder, SCP a BRP Pullpac cylinder and SRS an RSM Flat-Jac. The digits are the cylinder model, so SCR1010H holds an RC1010 and SCH1003H an RCH1003. The suffix gives the pump: H is a hand pump (a P142, P392 or P80 depending on the full set number), FP a P392FP foot pump, TB a P392 hand pump with a carry case and gauge, and XA an XA air pump. Enerpac lists the SCR1010H and SCH1003H as a cylinder, two-speed pump, 6 ft hose, calibrated gauge and gauge adaptor.
Service
Verified · SKU 5945427Every time i need to place an ordere with MRO the service is always prompt and friendly. Read more
Brand
BLACKSTAR
Model
BLS H50BS80 1 5/16 K2S
Brand
FYH Bearing
Model
NAF205EPL
Brand
SMC
Model
E200-F02-D
Brand
Martin Sprocket
Model
S2011
Brand
Maxi-Lift
Model
CC10X6 P G
Brand
BLACKSTAR
Model
BLS H60BS16 1 3/4 K2S
Brand
StrongHold
Model
SU-15401