We never sell your data to third parties
$530.31 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Accuracy
± (10 % MW + 2 % MEW)
Accuracy [K]
± 2 / + 8; (flow velocity > 20 % VMR and 20 °C: ± 2)
Ambient Temperature (°C)
-40...80
Ambient temperature [°C]
-40...80
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20; (scalable)
Analog End Point AEP (M/S)
6...30
Analog end point AEP [m/s]
6...30
Analog Start Point ASP (M/S)
0...24
Analog start point ASP [m/s]
0...24
Communication Interface
IO-Link
Connector
1 x M12; coding: A; Contacts: gold-plated
Current Consumption (Ma)
< 100
Current consumption [mA]
< 100
Dimensions (mm)
Ø 8 / L = 192
Dimensions [mm]
Ø 8 / L = 192
Display Range (M/S)
0...36
Display range [m/s]
0...36
Display Unit
6 x LED, green (%, m / s, l / min, m³ / h, °C, 10³)
Dynamic Response T05 / T09 (S)
30 (T09)
Dynamic response T05 / T09 [s]
30 (T09); (Flow velocity: ≥ 10 m/s)
Electrical Design
PNP / NPN
Factory Setting / Mode = (REL)
1237
File Number UL
E174189
Frequency At The End Point FRP (Hz)
100...1000
Frequency at the end point FRP [Hz]
100...1000
Frequency End Point, FEP (M/S)
6.6...30
Frequency end point, FEP [m/s]
6.6...30
Frequency of The Output (Hz)
0...1000
Frequency of the output [Hz]
0...1000
Greatest Sensitivity (M/S)
0.6...30
Greatest sensitivity [m/s]
0.6...30
Housing
Tubular
Installation
Recommended for Pipe Diameters
IO-Link Revision
1.1
Material
stainless steel (1.4404 / 316L); PBT-GF20; PBT-GF30
Materials (Wetted Parts)
Stainless Steel (1.4404 / 316L)
Max. load [Ω]
350
Max. voltage drop switching output DC [V]
2.5
Maximum Load (Ω)
350
Maximum Voltage Drop Switching Output DC (V)
2.5
Measured Values
alphanumeric display, red / green 4-digit
Measuring Principle
Calorimetric
Measuring Range (°C)
-20...100
Measuring range [°C]
-20...100
Media
Air
Medium Temperature (°C)
-20...100
Medium temperature [°C]
-20...100
Min. process cycle time [ms]
3
Minimum Process Cycle Time (Ms)
3
Mode = (ABS)
1238
MTTF (Years)
131
MTTF [years]
131
Number of Analog Outputs
1
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Operating Mode
Relative; Absolutely Gaseous
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC; (to SELV/PELV)
Output Function
Normally Open / Closed
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
250
Permanent current rating of switching output DC [mA]
250
Power-on Delay Time (S)
10
Power-on delay time [s]
10
Probe Length L (mm)
100
Probe length L [mm]
100
Process Connection
Clamp fitting Ø 8 mm
Process data analog
2
Process data binary
2
Protection
IP 65; IP 67
Protection Class
III
Repeatability
± (3 % MW + 0, 6 % MEW)
Required master port class
A
Reset Point Rp (M/S)
0.6...28.6
Reset point rP [m/s]
0.6...28.6
Resolution (M/S)
0.2
Resolution [m/s]
0.2
Resolution [°C]
0.2
Response Time (S)
7
Response time [s]
7
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9
Set Point SP (M/S)
2...30
Set point SP [m/s]
2...30
Setting Range (M/S)
0.6...60
Setting range [m/s]
0.6...30
Short-circuit Protection
Yes
SIO mode
Yes
Special feature
Gold-plated contacts
Storage Temperature (°C)
-40...100
Storage temperature [°C]
-40...100
Switching Status
2 x LED, yellow
Temperature Drift
± 0, 005 K / °C
Total Number of Outputs
2
Transmission type
COM2 (38, 4 kBaud)
Type of Short-circuit Protection
Yes (Non-latching)
- Measurement of flow and temperature at the same time
- Reliable airflow monitoring
- Red/green display for clear identification of the acceptable range
- With switching output, analog signal and IO-Link
- The process connection can be rotated for optimum alignment
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
NoTrax
Model
167S0035GN
Brand
Walter
Model
9937-G
Brand
EXAIR
Model
4880-ETC120
Brand
BLACKSTAR
Model
BLS 40B46
Brand
Rexnord
Model
HT4705-15PP
Brand
Walter
Model
4500V-0166