We never sell your data to third parties
IFM SI0558 SID10XDBAKOA/US-100 Flow monitor
MODEL SI0558
$650.32 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Brand
Baldor
Model
EM3665T
Brand
Baldor
Model
EHM2539T
Brand
SKF Seals
Model
18055
Brand
U.S. Seal Mfg.
Model
PS-357V
Adjustment of The Switch Point
Pushbuttons
Ambient Temperature (°C)
-25...60
Ambient temperature [°C]
-25...60
Connector
1 x M12; coding: A
Contact Rating
2 A, 24 V AC / DC
Current Consumption (Ma)
< 80
Current consumption [mA]
< 80
Dimensions (mm)
Ø 50 / L = 113
Dimensions [mm]
Ø 50 / L = 113
Greatest Sensitivity (Cm/S)
200...800
Greatest sensitivity [cm/s]
3...100
Housing
Tubular
Hysteresis (Cm/S)
2...5
Hysteresis [cm/s]
2...5; (for water 5...100 cm/s; 25 °C; Factory setting)
Installation Length EL (mm)
45
Installation length EL [mm]
45
Materials (Wetted Parts)
stainless steel (1.4404 / 316L); O-ring: FKM 80 Shore A
Max. temperature gradient of medium [K/min]
300
Maximum Temperature Gradient of Medium (K/Min)
300
Media
Liquids; Gases
Medium Temperature (°C)
-25...70
Medium temperature [°C]
-25...70
MTTF (Years)
351
MTTF [years]
351
Number of Digital Outputs
1
Number of inputs and outputs
Number of digital outputs: 1
Operating Voltage (V)
< 24 AC / 18...36 DC
Operating voltage [V]
< 24 AC / 18...36 DC; (to SELV/PELV)
Operating Voltage Tolerance (%)
-15...15
Operating voltage tolerance [%]
-15...15
Output Function
Normally Open
Output Signal
Switching Signal
Overload Protection
No
Pack quantity
1 pcs.
Power-on Delay Time (S)
10
Power-on delay time [s]
10
Probe Diameter (mm)
8.2
Probe diameter [mm]
8.2
Probe Length L (mm)
45
Probe length L [mm]
45
Process Connection
threaded connection M18 x 1, 5 Internal thread
Protection
IP 65; IP 67
Protection Class
III
Repeatability (Cm/S)
1...5
Repeatability [cm/s]
1...5
Response Time (S)
1...10
Response time [s]
1...2; (for a temperature gradient: 1 K/min)
Set Point SP (Cm/S)
20
Set point SP [cm/s]
20
Setting Range (Cm/S)
200...3000
Setting range [cm/s]
3...300
Short-circuit Protection
No
Storage Temperature (°C)
-25...100
Storage temperature [°C]
-25...100
Switch Point Accuracy (Cm/S)
± 2...± 10
Switch point accuracy [cm/s]
± 2...± 10; (for water 5...100 cm/s; 25 °C; Factory setting)
Temperature Drift (Cm/S X 1/K)
0.1
Temperature drift [cm/s x 1/K]
0.1; (for water 5...100 cm/s; 10...70 °C)
Total Number of Outputs
1
- Reliable monitoring of liquids and gases in pipes
- Variable process connection using adapters
- Easy setting of the switch points for quick set-up
- Robust stainless steel housing for use in harsh industrial environments
- LED bar graph for indication of switch point and flow
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Dormer Pramet
Model
5975610
Brand
Dormer Pramet
Model
5967363
Brand
Guardair
Model
74E018B
Brand
Linn Gear
Model
25B40SS
Brand
Champion
Model
900-B
Brand
Dodge
Model
P2B-DLAH-211-HT-DRY MOD