Accuracy (In The Measuring Range)
± (0, 8 % MW + 0, 5 % MEW)
Accuracy [K]
± 1 (77 °F; Q > 4 gpm)
Ambient Temperature (°F)
14...140
Ambient temperature [°F]
14...140
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20; (scalable)
Analog End Point (°F)
32...176
Analog end point [°F]
32...176
Analog Start Point (°F)
-4...140
Analog start point [°F]
-4...140
Analog Voltage Output (V)
0...10
Analog voltage output [V]
0...10; (scalable)
Communication Interface
IO-Link
Connector
1 x M12; coding: A; Contacts: gold-plated
Current Consumption (Ma)
< 150
Current consumption [mA]
< 150
Damping Process Value dAP (S)
0...5
Damping process value dAP [s]
0...5
Delay Time Programmable Ds, Dr (S)
0...50
Delay time programmable dS, dr [s]
0...50
Dimensions (mm)
200 x 103 x 117
Dimensions [mm]
200 x 103 x 117
Display Range (°F)
-40...212
Display range [°F]
-40...212
Display Unit
6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³)
Dp
Pressure Loss
Dynamic Response T05 / T09 (S)
T09 = 3 (Q > 4 gpm)
Dynamic response T05 / T09 [s]
T09 = 3 (Q > 4 gpm)
Electrical Design
PNP / NPN
File Number UL
E174189
Frequency of The Output (Hz)
0.1...10000
Frequency of the output [Hz]
0.1...10000
Housing
Rectangular
In Steps of
0.02 gal
In steps of [°F]
0.5
Inlet Pipe Length
3 x DN
Inputs
Counter Reset
Installation
Connection to pipe by means of an adapter
IO-Link Revision
1.1
Max. load [Ω]
500
Max. voltage drop switching output DC [V]
2
Maximum Load (Ω)
500
Maximum Voltage Drop Switching Output DC (V)
2
Measured Values
alphanumeric display, 4-digit
Measuring Dynamics
1:120
Measuring Principle
Magnetic-inductive
Measuring Range (°F)
-4...176
Measuring range [°F]
-4...176
Media
Conductive Liquids; Water; Water-based Media
Medium Temperature (°F)
14...194
Medium temperature [°F]
14...194
Min. load resistance [Ω]
2000
Min. process cycle time [ms]
5
Minimum Load Resistance (Ω)
2000
Minimum Process Cycle Time (Ms)
5
MTTF (Years)
85
MTTF [years]
85
Number of Analog Outputs
1
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Operating Voltage (V)
18...32 DC
Operating voltage [V]
18...32 DC; (to SELV/PELV)
Outlet Pipe Length
1 x DN
Output Function
Normally Open / Closed
Overload Protection
Yes
Permanent Current Rating of Switching Output DC (Ma)
250
Permanent current rating of switching output DC [mA]
250; (per output)
Power-on Delay Time (S)
5
Power-on delay time [s]
5
Process Connection
threaded connection G 2 external thread DN50 flat seal
Process data analog
3
Process data binary
2
Programming
alphanumeric display, 4-digit
Protection
IP 65; IP 67
Protection Class
III
Pulse Length (S)
0, 008...2
Pulse length [s]
0, 008...2
Pulse Output
Flow Rate Meter
Pulse Value
0.02...160 E06 gal
Q
Volumetric Flow Quantity
Repeatability
± 0, 2% MEW
Required master port class
A
Reset Point Rp (°F)
-3...175
Reset point rP [°F]
-3...175
Resolution (°F)
0.5
Resolution [°F]
0.5
Response Time (S)
0.35
Response time [s]
0.35; (dAP = 0)
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9 CDV
Set Point SP (°F)
-2...176
Set point SP [°F]
-2...176
Short-circuit Protection
Yes
SIO mode
Yes
Special feature
Gold-plated contacts
Storage Temperature (°F)
-13...176
Storage temperature [°F]
-13...176
Switching Status
2 x LED, yellow
Temperature Drift
± 0, 0185 °F / K
Total Number of Outputs
2
Transmission type
COM2 (38, 4 kBaud)
Type of Short-circuit Protection
Yes (Non-latching)
- Operating voltage 18...32 DC
- (according to EN 50178 SELV/PELV) V
- PNP/NPN
- M12 Connector
- Gold-plated contacts
- totaliser function, empty pipe detection, for industrial applications
The industrial sensor is an industrial device category used to serve its stated function within industrial automation equipment. It is incorporated into equipment arrangements where that general function is needed. The configuration details in the list identify this cataloged item and should be considered with the product technical documentation and applicable machine requirements. Catalog number SM2001 distinguishes this item in the equipment record. This paragraph provides general device context only; product-specific technical details are limited to the listed source information.
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Timken
Model
LO524
Brand
Cooper Wiring
Model
TCI254
Brand
Timken
Model
25004-2121
Brand
Thomson Linear
Model
511U45F3CG2
Brand
Falk
Model
10011259
Brand
FEIN
Model
63131045010
Brand
IFM
Model
AC2258