AL16-30-10-80

Image for Illustration purposes only. Actual product may vary

View in markdown

ABB AL16-30-10-80 Contactor | AL16-30-10-80

MODEL AL16-30-10-80

BRAND

ABB

SKU

6151211

UOM

each

Call for Pricing - 888-671-2883

Typically Ships in: 1 day

Returnable: Yes

ASEFA certificate

ASEFA_05203BT

CB certificate

CB_FR_617239A

CCC certificate

CCC_2004010304112227

Climatic withstand

acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II

Coil consumption

Average Holding Value, from Warm State 3 W Average Pull-in Value, from Cold State 3 W

Coil operating limits

(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at 55 C) C

Connecting capacity auxiliary circuit

Flexible with Cable End 0.75 ... 2.5 mm Rigid Cable 1 ... 4 mm

Connecting capacity main circuit

Flexible with Cable End 0.75 ... 2.5 mm Rigid Cable 1 ... 4 mm

Connecting terminals (delivered in open position) main poles

M 3.5 (+,-) pozidriv 2 screw with cable clamp

Conventional free-air thermal current (Ith)

acc. to IEC 60947-4-1, Open Contactors q = 40 C 30 A acc. to IEC 60947-5-1, q = 40 C 16 A

CSA certificate

CSA_1041746

cUL certificate

UL_20160205-E312527-10-2

Data sheet, technical information

1SBC100122C0202_Ch02

Declaration of conformity - CE

1SBD250804U1000

Degree of protection

acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20

ETIM 4

EC000066 - Magnet contactor, AC-switching

ETIM 5

EC000066 - Magnet contactor, AC-switching

ETIM 6

EC000066 - Power contactor, AC switching

GL certificate

GL_26144_05HH

GOST certificate

GOST_POCCFRME77B07175

LOVAG certificate

LOVAG_FR03023-FR03029

Max electrical switching frequency

AC-1 600 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour

Max mechanical switching frequency

3600 cycles per hour

Max operating altitude permissible

3000 m

Mechanical durability

10 million

Number of auxiliary contacts NC

0

Number of auxiliary contacts NO

1

Number of main contacts NC

0

Number of main contacts NO

3

Object classification code

Q

Rated breaking capacity AC-3 acc. to IEC 60947-4-1

8 x Ie AC-3

Rated control circuit voltage (Uc)

DC Operation 12 V

Rated frequency

Supply Circuit 50 Hz Supply Circuit 60 Hz

Rated impulse withstand voltage (U imp)

8 kV

Rated insulation voltage (Ui)

acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V

Rated making capacity AC-3 acc. to IEC 60947-4-1

10 x Ie AC-3

Rated operational current AC-1 (Ie)

(690 V) 40 C 30 A (690 V) 55 C 27 A (690 V) 70 C 23 A

Rated operational current AC-15 (Ie)

(220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A

Rated operational current DC-13 (Ie)

(125 V) 1.1 / 138 A (24 V) 6 / 144 A (250 V) 0.55 / 138 A (48 V) 2.8 / 134 A (72 V) 2 / 144 A

Rated operational power AC-3 (Pe)

(220 / 230 / 240 V) 4 kW (380 / 400 V) 7.5 kW (415 V) 9 kW (440 V) 9 kW (500 V) 9 kW (690 V) 9 kW

Rated operational voltage

Auxiliary Circuit 690 V Main Circuit 690 V

RoHS information

1SBD350051R1000

RoHS status

Following EU Directive 2002/95/EC August 18, 2005 and amendment

Short-circuit protective devices

Auxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 32 A

Terminal type

Screw terminals

UL listing card

UL_E312527

Ambient air temperature: Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 C Close to Contactor for Storage -60 ... +80 C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 C Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 C

Max breaking capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 100 A

Operate time: Between Coil Energization and NO Contact Closing 50 ... 100 ms Between Coil De-energization and NO Contact Opening 10 ... 17 ms Between Coil De-energization and NC Contact Closing 16 ... 27 ms

Rated operational current AC-3 (Ie): (220 / 230 / 240 V) 55 C 17 A (380 / 400 V) 55 C 17 A (415 V) 55 C 17 A (440 V) 55 C 16 A (500 V) 55 C 14 A (690 V) 55 C 10 A

Rated short-time withstand current (Icw): at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 140 A at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 30 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 60 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 300 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 80 A for 0.1 s 140 A for 1 s 100 A

Resistance to shock acc. to IEC 60068-2-27: Closed, Shock Direction A 20 g Open, Shock Direction A 10 g Closed, Shock Direction B1 15 g Open, Shock Direction B1 5 g Shock Direction B2 10 g Closed, Shock Direction C1 20 g Open, Shock Direction C1 8 g Closed, Shock Direction C2 14 g Open, Shock Direction C2 8 g